Determination of H relaxation times of water in human bone marrow by fat‐suppressed turbo spin echo in comparison to MR spectroscopic methods
- 1 May 1996
- journal article
- research article
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 6 (3) , 541-548
- https://doi.org/10.1002/jmri.1880060318
Abstract
Relaxation times of water were measured in human vertebral bodies by a fat-suppressed dual-echo turbo spin echo/turbo inversion recovery MRI sequence. Comparison was made with T1 and T2 values obtained by localized 1H-MR spectroscopy. The accuracy of the results and the diagnostic potential of the fast quantitative MRI technique were evaluated in 20 volunteers, 11 patients with osteoporosis, 6 patients with lymphoma, and 6 patients with bone marrow metastasis. No significant alterations of T1 and T2 relaxation times of water and fat were found in osteoporosis. With both methods, an increase in the T1 values of the water resonance by 16% was observed in lymphomas, which was highly significant (P < .001) in the MRS measurements, and an elevation by the same amount was obtained by the MRI sequence for the metastases (P = .040). A strong reduction of fat fraction was quantified by MRS in the tumorous cases. T2 of the water resonance increased by more than 30% (P < .003) in metastases. Water T2 values obtained by the MRI sequence showed systematic deviations from the MRS results, especially at short echo spacings.Keywords
This publication has 19 references indexed in Scilit:
- T1 Maps by K-Space Reduced Snapshot-FLASH MRIJournal of Computer Assisted Tomography, 1992
- Quantitation of the susceptibility difference between trabecular bone and bone marrow: Experimental studiesMagnetic Resonance in Medicine, 1991
- Quantitative study of the susceptibility difference between trabecular bone and bone marrow: Computer simulationsMagnetic Resonance in Medicine, 1991
- Trabecular structure: preliminary application of MR interferometry.Radiology, 1991
- High‐speed multislice T1 mapping using inversion‐recovery echo‐planar imagingMagnetic Resonance in Medicine, 1990
- Hematologic bone marrow disorders: quantitative chemical shift MR imaging.Radiology, 1988
- Fast Field Echo imaging: An overview and contrast calculationsMagnetic Resonance Imaging, 1988
- RARE imaging: A fast imaging method for clinical MRMagnetic Resonance in Medicine, 1986
- The Effects of Bone on Proton NMR Relaxation Times of Surrounding LiquidsInvestigative Radiology, 1986
- Active bone marrow distribution as a function of age in humansPhysics in Medicine & Biology, 1981