Myocardial Perfusion Imaging Based on the Blood Oxygen Level–Dependent Effect Using T 2 -Prepared Steady-State Free-Precession Magnetic Resonance Imaging
- 7 September 2004
- journal article
- research article
- Published by Wolters Kluwer Health in Circulation
- Vol. 110 (10) , 1284-1290
- https://doi.org/10.1161/01.cir.0000140673.13057.34
Abstract
Background— The decision to perform coronary revascularization procedures may hinge on assessment of myocardial perfusion reserve. Blood oxygen level–dependent (BOLD) MRI is a potential method to detect the effects of regional variations in myocardial blood flow during vasodilation. Methods and Results— We imaged dogs (n=13) on a 1.5-T whole-body MRI scanner using a new T 2 -prepared steady-state free-precession (SSFP) MRI pulse sequence sensitive to BOLD contrast. Images (in-plane resolution ≈1 mm 2 ) of 5 short-axis and 2 long-axis slices of the heart were acquired during graded levels of adenosine infusion via a surgically placed left circumflex (LCx) catheter (n=11) or via a right atrial catheter in animals with an LCx occluder (n=2). Relative myocardial perfusion was measured with the use of fluorescent microspheres. Signal intensity changes in myocardium subtended by the left anterior descending coronary artery were compared with those in the LCx region. Unprocessed T 2 -weighted images revealed changes in signal intensity corresponding to areas of regional vasodilation or reduced myocardial perfusion reserve during systemic vasodilation. At maximal vasodilation, the signal intensity ratio in the LCx versus left anterior descending territories increased by 33±4% compared with baseline, corresponding to a 3.8±0.3-fold increase in relative perfusion ( P R =0.80, P Conclusions— T 2 -prepared SSFP BOLD imaging is a promising method to determine an index of myocardial perfusion reserve in this animal model.Keywords
This publication has 16 references indexed in Scilit:
- MR assessment of left ventricular function: Quantitative comparison of fast imaging employing steady‐state acquisition (FIESTA) with fast gradient echo cine techniqueJournal of Magnetic Resonance Imaging, 2002
- Three‐dimensional true‐FISP imaging of the coronary arteries: Improved contrast with T2‐preparationJournal of Magnetic Resonance Imaging, 2002
- Clinical relevance of a normal myocardial perfusion scintigraphic studyJournal of Nuclear Cardiology, 1997
- Myocardial intensity changes associated with flow stimulation in blood oxygenation sensitive magnetic resonance imagingMagnetic Resonance in Medicine, 1996
- Myocardial signal response to dipyridamole and dobutamine: Demonstration of the BOLD effect using a double‐echo gradient‐echo sequenceMagnetic Resonance in Medicine, 1996
- Blood oxygenation dependence of t1 and t2 in the isolated, perfused rabbit heart at 4.7tMagnetic Resonance in Medicine, 1995
- Effect of cardiac flow on gradient recalled echo images of the canine heartNMR in Biomedicine, 1994
- Contrast‐enhanced first pass myocardial perfusion imaging: Correlation between myocardial blood flow in dogs at rest and during hyperemiaMagnetic Resonance in Medicine, 1993
- Endogenous susceptibility contrast in myocardium during apnea measured using gradient recalled echo planar imagingMagnetic Resonance in Medicine, 1993
- First-pass nuclear magnetic resonance imaging studies using gadolinium-DTPA in patients with coronary artery diseaseJournal of the American College of Cardiology, 1991