Ionized calcium in normal serum, ultrafiltrates, and whole blood determined by ion-exchange electrodes
Open Access
- 1 February 1970
- journal article
- Published by American Society for Clinical Investigation in Journal of Clinical Investigation
- Vol. 49 (2) , 318-334
- https://doi.org/10.1172/jci106241
Abstract
Ion-exchange calcium electrodes represent the first practical method for the direct measurement of ionized calcium [Ca++] in biologic fluids. Using both “static” and “flow-through” electrodes, serum [Ca++] was within a rather narrow range: 0.94-1.33 mmoles/liter (mean, 1.14 mmoles/liter). Within a given individual, [Ca++] varied only about 6% over a several month period. Consistent pH effects on [Ca++] were observed in serum and whole blood, [Ca++] varying inversely with pH. Less consistent pH effects were also noted in ultrafiltrates, believed to largely represent precipitation of certain calcium complexes from a supersaturated solution. Heparinized whole blood [Ca++] was significantly less than in corresponding serum at normal blood pH, related to the formation of a calcium-heparin complex. [Ca++] in ultrafiltrates represented a variable fraction (66.7-90.2%) of total diffusible calcium. There was no apparent correlation between serum ionized and total calcium concentrations. Thus, neither serum total calcium nor total ultrafiltrable calcium provided a reliable index of serum [Ca++]. Change in serum total calcium was almost totally accounted for by corresponding change in protein-bound calcium [CaProt]. About 81% of [CaProt] was estimated to be bound to albumin and about 19% to globulins. From observed pH, serum protein, and [CaProt] data, a nomogram was developed for estimating [CaProt] without ultrafiltration. Data presented elsewhere indicate that calcium binding by serum proteins obeys the mass-law equation for a monoligand association. This was indicated in the present studies by a close correspondence of observed serum [Ca++] values with those predicted by the McLean-Hastings nomogram. While these electrodes allow study of numerous problems not possible previously, they have not been perfected to the same degree of reliability obtainable with current pH electrodes. The commercial (Orion flow-through) electrode is: (a) expensive. (b) requires periodic replacement of membranes, and (c) has not yet been thermostated. As with blood pH measurements. (d) electrode response is logarithmic, i.e. small potential errors generate rather large [Ca++] errors. (e) loss of CO2 should be prevented, and (f) errors due to other cations must be considered under certain conditions. Despite these limitations, we believe the electrode represents a major advance in calcium metabolism.Keywords
This publication has 22 references indexed in Scilit:
- Calcium in normal human gastric juice. A four-component model with speculation on the relation of calcium to pepsin secretion.1968
- Calcium-Selective Electrode with Liquid Ion ExchangerScience, 1967
- THE DETERMINATION OF SODIUM IN BODY FLUIDS BY THE GLASS ELECTRODE*Journal of Clinical Investigation, 1963
- THE SEPARATE EFFECTS OF HYPERPARATHYROIDISM, HYPERCALCEMIA OF MALIGNANCY, RENAL FAILURE, AND ACIDOSIS ON THE STATE OF CALCIUM, PHOSPHATE, AND OTHER IONS IN PLASMA*Journal of Clinical Investigation, 1962
- Ultracentrifugal Analysis of Protein-bound and Free Calcium in Human SerumJournal of Biological Chemistry, 1960
- The ionized, complexed, and protein-bound fractions of calcium in plasma; an investigation of patients with various diseases which affect calcium metabolism, with an additional study of the role of calcium ions in the prevention of tetany.1958
- Determination of the ionised and ultrafilterable calcium of normal human plasmaClinica Chimica Acta; International Journal of Clinical Chemistry, 1957
- THE ULTRAFILTRABLE CALCIUM OF HUMAN SERUM. I. ULTRAFILTRATION METHODS AND NORMAL VALUES 1Journal of Clinical Investigation, 1957
- ULTRAFILTRATION STUDIES ON CALCIUM AND PHOSPHORUS IN HUMAN SERUM1952
- Inorganic constituents of cerebrospinal fluidBiochemical Journal, 1932