Performance Characteristics of the COBAS Amplicor Hepatitis C Virus (HCV) Monitor, Version 2.0, International Unit Assay and the National Genetics Institute HCV Superquant Assay
Open Access
- 1 March 2002
- journal article
- Published by American Society for Microbiology in Journal of Clinical Microbiology
- Vol. 40 (3) , 768-773
- https://doi.org/10.1128/jcm.40.3.768-773.2002
Abstract
The COBAS Amplicor Hepatitis C Virus (HCV) Monitor assay, version 2.0, which reports in international units per milliliter, was compared to the assay reported in copies per milliliter by analyzing dilution series and clinical plasma samples by both methods. In addition, the Amplicor international unit assay was compared to the National Genetics Institute HCV Superquant assay. The dilution series ranged from R 2 = 0.981; n = 28; S y/x (standard error of the estimate) = 0.129. The linearity of the Amplicor international units-per-milliliter assay was as follows: observed = 0.886(expected) + 0.437; R 2 = 0.983; n = 30. The linearity of the Superquant assay was as follows: observed= 0.918 (expected) + 0.436; R 2 = 0.986; n = 32. Deming regression analysis comparing the Amplicor and Superquant assays was calculated as follows: Superquant = 1.066(Amplicor) − 0.0197; R 2 = 0.908; S y/x = 0.308; n = 28. The Amplicor and Superquant assays were linear through the range of 600 to 600,000 IU of HCV RNA/ml and ∼300 to 5,000,000 HCV RNA copies/ml, respectively. The narrow range of the Amplicor assay means that some samples will require dilution and retesting for accurate quantification above 600,000 IU of HCV RNA/ml. The Amplicor and Superquant assays agreed well within the range of 600 to 600,000 IU of HCV RNA/ml (∼1,000 to ∼1,000,000 HCV RNA copies/ml). Overall, the Amplicor and Superquant assays agree well, and results obtained in one assay could be expected to compare well with results from the other when reported in copies per milliliter.Keywords
This publication has 19 references indexed in Scilit:
- Detection of residual hepatitis C virus RNA by transcription-mediated amplification in patients with complete virologic response according to polymerase chain reaction-based assaysHepatology, 2000
- Standardization of Hepatitis C Virus RNA QuantificationHepatology, 2000
- Performance Characteristics of the COBAS AMPLICOR Hepatitis C Virus MONITOR Test, Version 2.0American Journal of Clinical Pathology, 2000
- Establishment of the First International Standard for Nucleic Acid Amplification Technology (NAT) Assays for HCV RNAVox Sanguinis, 1999
- Comparative Evaluation of Hepatitis C Virus Rna Quantitation by Branched Dna, Nasba, and Monitor AssaysHepatology, 1999
- Comparison of 3 Quantitative HCV RNA Assays - Accuracy of Baseline Viral Load to Predict Treatment Outcome in Chronic Hepatitis CScandinavian Journal of Infectious Diseases, 1998
- Prediction of response during interferon alfa 2b therapy in chronic hepatitis C patients using viral and biochemical characteristics: A comparisonHepatology, 1997
- Factors predictive of a beneficial response to therapy of hepatitis CHepatology, 1997
- Diagnosis of hepatitis CHepatology, 1997
- Correlation of serum HCV RNA and alanine aminotransferase levels in chronic hepatitis C patients during treatment with ribavirinJournal of Gastroenterology and Hepatology, 1994