Mechanism of Peptide Separations by Solid Phase Extraction Capillary Electrophoresis at Low pH
- 1 January 1996
- journal article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 68 (2) , 306-314
- https://doi.org/10.1021/ac9503217
Abstract
A device for on-line extraction and concentration of peptides from a dilute sample matrix prior to direct capillary electrophoretic analysis is described. The technique, termed solid phase extraction capillary electrophoresis (SPE-CE), can facilitate analysis of peptides in the low nanograms per milliliter range. Peptides from a sample matrix are adsorbed on a reversed phase resin (C-8 or C-18) cartridge in-line with an uncoated fused-silica capillary and subsequently released for free zone electrophoresis by injection of an organic elutant. Unlike previous designs and commercially available packed-inlet capillaries, the device is easily constructed from common laboratory materials and is applicable to a wide range of conventional instrumentation and methods. This device and method has been developed for use in our laboratory as a stand-alone preparative technique, specifically to provide a second-dimensional orthogonal separation of biologically derived HPLC fractions of peptides in a single analysis. To this end, extensive effort was required in both device construction and method development to attain the successful separations which are reported in this study. Extractions of dilute peptide mixtures from sample injections exceeding, but not limited to, 20 times (48 μL) the capillary volume with apparent recovery greater than 80% are shown. The selectivity of extraction of individual components of a very dilute peptide mixture (31 ng/mL with 280 μL of sample injected) is presented. The ability to efficiently extract the individual peptides from the sample was found to be concentration-dependent for the individual peptide components over a 1600-field dilution of a common calibration mixture of nine model peptides. Varying the injected volume of elution buffer demonstrated the importance of minimizing the amount of buffer used to desorb peptides to maximize the resolution of individual peptides. This study highlights implementation for direct SPE-CE for peptide analysis and discusses the SPE tip-induced mechanism through which reversal in electroosmotic flow occurs.Keywords
This publication has 20 references indexed in Scilit:
- Sensitivity enhancement and second-dimensional information from solid phase extraction-capillary electrophoresis of entire high-performance liquid chromatography fractionsElectrophoresis, 1995
- The use of solid phase concentrators for on‐line preconcentration of metallothionein prior to isoform separation by capillary zone electrophoresisElectrophoresis, 1995
- Time course analysis of a microsomal incubation of a therapeutic drug using preconcentration capillary electrophoresis (PC-CE)Journal of High Resolution Chromatography, 1994
- Influence of temperature on the sieving effect of different polymer matrixes in capillary SDS gel electrophoresis of proteinsAnalytical Chemistry, 1993
- Trace analysis of proteins by capillary zone electrophoresis with on‐column transient isotachophoretic preconcentrationElectrophoresis, 1993
- Electrophoretic separation of S. Pombe chromosomes in polyacrylamide solutions using a constant fieldBiochemical and Biophysical Research Communications, 1991
- Preparation and evaluation of a bimodal size-exclusion chromatography column containing a mixture of two silicas of different pore diameterAnalytical Chemistry, 1991
- Fluorescence detection in capillary electrophoresis: evaluation of derivatizing reagents and techniquesAnalytical Chemistry, 1991
- Zone electrophoresis in open-tubular glass capillariesAnalytical Chemistry, 1981
- Free zone electrophoresisChromatographic Reviews, 1967