A New Method to Improve In-Bore Middle Cerebral Artery Occlusion in Rats

Abstract
Background and Purpose—In-bore middle cerebral artery occlusion (MCAO) enables investigators to acquire preischemic MRI data and to image ischemic changes immediately after occlusion. We have developed a highly successful in-bore MCAO method. This study describes the methods and pertinent techniques. Methods—Sixty-seven Sprague-Dawley rats were subjected to temporary (n=36) or permanent (n=31) MCAO. The occluding device consisted of a supporting tubing, a driving line, and a silicone-coated 4-0 nylon suture occluder. Outside the magnet, the occluder was positioned in the carotid canal. MCAO was achieved in the magnet bore by remotely advancing the driving line until resistance was felt. Diffusion-weighted imaging (DWI) and perfusion-weighted imaging (PWI) were acquired before and immediately after occlusion and were used to document the presence of MCAO. Results—Fifty-nine (88.1%) rats were successfully occluded, demonstrating hyperintensity on DWI, perfusion deficits on PWI, and no subarachnoid hemorrhag...

This publication has 24 references indexed in Scilit: