Precise measurement of vertebral bone density using computed tomography without the use of an external reference phantom
- 1 February 1989
- journal article
- Published by Springer Nature in Journal of Digital Imaging
- Vol. 2 (1) , 31-38
- https://doi.org/10.1007/bf03168013
Abstract
Bone density measurement by quantitative computed tomography (QCT) commonly uses an external reference phantom to decrease scan-to-scan and scanner-to-scanner variability. However, the peripheral location of these phantoms and other phantom variables is also responsible for a measurable degradation in accuracy and precision. Due to non-uniform artifacts such as beam hardening, scatter, and volume averaging, the ideal reference phantom should be as close to the target tissue as possible. This investigation developed and tested a computer program that uses paraspinal muscle and fat tissue as internal reference standards in an effort to eliminate the need for an external phantom. Because of their proximity, these internal reference tissues can be assumed to reflect more accurately the local changes in the x-ray spectra and scatter distribution at the target tissue. A user interactive computerized histogram plotting technique enabled the derivation of reproducible CT numbers for muscle, fat, and trabecular bone. Preliminary results indicate that the use of internal reference tissues with the histogram technique may improve reproducibility of scan-to-scan measurements as well as inter-scanner precision. Reproducibility studies on 165 images with intentional region-of-interest (ROI) mispositioning of 1.5, 2.5, or 3.5 mm yielded a precision of better than 1% for normals and 1% to 2% for osteoporotic patients—a twofold improvement over the precision from similar tests using the standard technique with an external reference phantom. Such improvements in precision are essential for QCT to be clinically useful as a noninvasive modality for measurement of the very small annual changes in bone mineral density.Keywords
This publication has 27 references indexed in Scilit:
- Quantitative Computed Tomography Scanning for Measurement of Bone and Bone Marrow Fat ContentInvestigative Radiology, 1987
- Bone density in diagnosis of osteoporosis: Thresholds and breakpointsCalcified Tissue International, 1987
- Two Postprocessing CT Techniques for Determining the Composition of Trabecular BoneInvestigative Radiology, 1987
- Bone Mineral Screening for OsteoporosisNew England Journal of Medicine, 1987
- Quantitative Computed Tomography for Spinal Density Measurement Factors Affecting PrecisionInvestigative Radiology, 1985
- Quantitative computed tomography for prediction of vertebral fracture riskBone, 1985
- Errors in measuring trabecular bone by computed tomography due to marrow and bone compositionCalcified Tissue International, 1983
- Repositioning errors in measurement of vertebral attenuation values by computed tomographyThe British Journal of Radiology, 1983
- Precise Measurement of Vertebral Mineral Content Using Computed TomographyJournal of Computer Assisted Tomography, 1980
- Measurement of effective atomic number and electron density using an EMI scannerNeuroradiology, 1976