Implantable cardioverter-defibrillator therapy in the absence of significant symptoms. Rhythm diagnosis and management aided by stored electrogram analysis.
- 1 June 1993
- journal article
- abstracts
- Published by Wolters Kluwer Health in Circulation
- Vol. 87 (6) , 1897-1906
- https://doi.org/10.1161/01.cir.87.6.1897
Abstract
BACKGROUND This report describes the value of stored ventricular electrogram analysis in the diagnosis and management of patients experiencing minimal or no symptoms before implantable cardioverter-defibrillator (ICD) therapy. METHODS AND RESULTS The study population included 48 patients who received the Cadence Tiered Therapy Defibrillator System, an investigational third-generation ICD with ventricular electrogram storage capabilities. Criteria for arrhythmia diagnosis were based on analysis of the electrogram rate, RR interval variability, and morphology. Twenty-nine of the 48 patients (60%) experienced at least one episode of antitachycardia pacing or shock (one shock or more in 25 of 29 patients) that was preceded by minimal or no symptoms during a mean follow-up of 15.1 +/- 7.8 months. There were 194 tachycardia episodes registered by the device, including 101 for which ventricular electrograms were stored and available for analysis. Of the 101 stored electrograms, 74 were classified as ventricular tachycardia (VT), 24 as non-VT rhythms (atrial fibrillation, 13; supraventricular tachycardia, six; rate-sensing lead disruption, four; T wave oversensing, one), and only three as indeterminate rhythms. Based on the electrogram analysis, changes in tachycardia detection criteria and/or antiarrhythmic drug regimens were implemented and were associated with a reduction in the number of device responses for non-VT rhythms from 24 during the initial study period to three during 11.0 +/- 7.2 months of additional follow-up. CONCLUSIONS ICD responses in the absence of symptoms are relatively common in third-generation devices with antitachycardia pacing capabilities. Despite potential limitations such as the effect of bundle branch block on the electrogram morphology during supraventricular tachycardia, the availability of electrogram storage capabilities allowed a presumptive diagnosis of the events precipitating asymptomatic device responses. Device reprogramming based on analysis of stored electrograms was associated with a dramatic reduction in the incidence of ICD responses for non-VT rhythms.Keywords
This publication has 22 references indexed in Scilit:
- Use of Bipolar Recordings from Patch‐Patch and Rate Sensing Leads to Distinguish Ventricular Tachycardia from Supraventricular Rhythms in Patients with Implantable Cardioverter DefibrillatorsPacing and Clinical Electrophysiology, 1991
- Antitachycardia devices: Realities and promisesJournal of the American College of Cardiology, 1991
- Value of ventricular electrogram recordings in the diagnosis of arrhythmias precipitating electrical device shock therapyJournal of the American College of Cardiology, 1991
- Clinical Performance of the Implantable Cardioverter Defibrillator: Electrocardiographic Documentation of 101 Spontaneous DischargesPacing and Clinical Electrophysiology, 1991
- Cardiac rhythm precipitating automatic implantable cardioverter-defibrillator discharge in outpatients as detected from transtelephonic electrocardiographs recordingsThe American Journal of Cardiology, 1991
- Time to first shock and clinical outcome in patients receiving an automatic implantable cardioverter-defibrillatorJournal of the American College of Cardiology, 1989
- The automatic implantable cardioverter defibrillator: Efficacy, complications and survival in patients with malignant ventricular arrhythmiasJournal of the American College of Cardiology, 1988
- Automatic Implantable Defibrillator Discharge Resulting From Routine Pacemaker ProgrammingPacing and Clinical Electrophysiology, 1988
- Practical aspects of automatic cardioverter/defibrillator implantationAmerican Heart Journal, 1984
- Termination of Malignant Ventricular Arrhythmias with an Implanted Automatic Defibrillator in Human BeingsNew England Journal of Medicine, 1980