A Method for Sampling Halothane and Enflurane Present in Trace Amounts in Ambient Air

Abstract
A method for the sampling of small amounts of halothane and enflurane [which may be hazardous to operating room personnel] in ambient air is described. Sampling is performed by drawing air through a sampling tube packed with Porapak Q, which adsorbs the anesthetic agent. The amount absorbed is determined by gas chromatography after thermal desorption. This method can be used for spot or personal sampling or for determining mean whole-room concentrations over relatively long periods (several hours).

This publication has 0 references indexed in Scilit: