Consensus on Microembolus Detection by TCD
- 1 March 1998
- journal article
- other
- Published by Wolters Kluwer Health in Stroke
- Vol. 29 (3) , 725-729
- https://doi.org/10.1161/01.str.29.3.725
Abstract
—Transcranial Doppler ultrasound is capable of detecting microembolic material, both gaseous and solid, within the intracranial cerebral arteries. To avoid discrediting this promising and exciting new technique, experts in this field met in January 1997 in Frankfurt, Germany, to discuss the limitations and problems of embolus detection and to determine guidelines for its proper use in clinical practice, as well as in scientific investigations. In particular, the authors suggest that studies report the following parameters: (1) ultrasound device, (2) transducer type and size, (3) insonated artery, (4) insonation depth, (5) algorithms for signal intensity measurement, (6) scale settings, (7) detection threshold, (8) axial extension of sample volume, (9) fast Fourier transform (FFT) size (number of points used), (10) FFT length (time), (11) FFT overlap, (12) transmitted ultrasound frequency, (13) high-pass filter settings, and (14) recording time. There was agreement that no current system of automatic embolus detection has the required sensitivity and specificity for clinical use.Keywords
This publication has 10 references indexed in Scilit:
- Variability in occurrence of embolic signals in long term transcranial Doppler recordingsNeurological Research, 1996
- Asymptomatic cerebral embolic signals in symptomatic and asymptomatic carotid artery diseaseBrain, 1995
- The Effect of Different Settings of Ultrasound Pulse Amplitude, Gain and Sample Volume on the Appearance of Emboli Studied in a Transcranial Doppler ModelCerebrovascular Diseases, 1994
- Processing Doppler ultrasound signals from blood-borne emboliUltrasound in Medicine & Biology, 1994
- A real-time and fine resolution analyser used to estimate the instantaneous energy distribution of Doppler signalsUltrasound in Medicine & Biology, 1994
- Pulse Doppler ultrasound detection, characterization and size estimation of emboli in flowing bloodIEEE Transactions on Biomedical Engineering, 1994
- Computerized detection of cerebral emboli and discrimination from artifact using Doppler ultrasound.Stroke, 1993
- Silent cerebral embolism caused by neurologically symptomatic high-grade carotid stenosisBrain, 1993
- Digital audio tape as a method of storing Doppler ultrasound signalsPhysiological Measurement, 1993
- MRC European Carotid Surgery Trial: interim results for symptomatic patients with severe (70-99%) or with mild (0-29%) carotid stenosisThe Lancet, 1991