Cardiovascular Flow Measurement with Phase-Contrast MR Imaging: Basic Facts and Implementation
Top Cited Papers
- 1 May 2002
- journal article
- Published by Radiological Society of North America (RSNA) in RadioGraphics
- Vol. 22 (3) , 651-671
- https://doi.org/10.1148/radiographics.22.3.g02ma11651
Abstract
Phase-contrast magnetic resonance (MR) imaging is a well-known but undervalued method of obtaining quantitative information on blood flow. Applications of this technique in cardiovascular MR imaging are expanding. According to the sequences available, phase-contrast measurement can be performed in a breath hold or during normal respiration. Prospective as well as retrospective gating techniques can be used. Common errors in phase-contrast imaging include mismatched encoding velocity, deviation of the imaging plane, inadequate temporal resolution, inadequate spatial resolution, accelerated flow and spatial misregistration, and phase offset errors. Flow measurements are most precise if the imaging plane is perpendicular to the vessel of interest and flow encoding is set to through-plane flow. The sequence should be repeated at least once, with a high encoding velocity used initially. If peak velocity has to be estimated, flow measurement is repeated with an adapted encoding velocity. The overall error of a phase-contrast flow measurement comprises errors during prescription as well as errors that occur during image analysis of the flow data. With phase-contrast imaging, the overall error in flow measurement can be reduced to less than 10%, an acceptable level of error for routine clinical use.Keywords
This publication has 50 references indexed in Scilit:
- MR measurement of coronary blood flowJournal of Magnetic Resonance Imaging, 1999
- MR velocity mapping of tricuspid flow: Correction for through‐plane motionJournal of Magnetic Resonance Imaging, 1997
- Magnetic Resonance Imaging Assessment of the Severity of Mitral RegurgitationCirculation, 1995
- Quantification of collateral blood flow in coarctation of the aorta by velocity encoded cine magnetic resonance imaging.Circulation, 1994
- Rapid MR imaging of blood flow with a phase-sensitive, limited-flip-angle, gradient recalled pulse sequence: preliminary experience.Radiology, 1990
- Human abdominal aorta: comparative measurements of blood flow with MR imaging and multigated Doppler US.Radiology, 1989
- Verification and evaluation of internal flow and motion. True magnetic resonance imaging by the phase gradient modulation method.Radiology, 1985
- NMR blood flow imaging using multiecho, phase contrast sequencesMedical Physics, 1985
- A flow velocity zeugmatographic interlace for NMR imaging in humansMagnetic Resonance Imaging, 1982
- Blood Flow Rates by Nuclear Magnetic Resonance MeasurementsScience, 1959