Is a Cooled Tip Catheter the Solution for the Ablation of the Cavotricuspid Isthmus?
- 1 January 2003
- journal article
- clinical trial
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 26 (1p2) , 328-331
- https://doi.org/10.1046/j.1460-9592.2003.00043.x
Abstract
To test the theoretical superiority of irrigated tip catheters to achieve complete cavotricuspid isthmus block, a 4-mm cooled tip catheter was compared to a conventional 8-mm tip catheter with a double temperature sensor in the cavotricuspid isthmus (CTI) ablation. The study prospectively enrolled 60 patients (47 men, mean 65 +/- 10 years) with common flutter divided in group 1 (n = 30) assigned to an 8-mm tip catheter versus group 2 (n = 30), assigned to an internal circuit, irrigated tip catheter. Linear radiofrequency applications were performed in a point-by-point protocol to achieve complete CTI block. Complete CTI block was achieved in 29 patients in each group. Mean durations of procedure and fluoroscopy were 91 versus 90 and 40 versus 33 minutes in group 1 versus 2, respectively, (NS). The mean number/patient of RF pulses to interrupt atrial flutter was four in group 1 and eight in group 2 (P = 0.034), and 11 and 13, respectively, to interrupt CTI conduction (NS). The total energy delivered was similar in both groups (29,237 vs 23,236 W/s, NS). CTI ablation with a conventional 8-mm tip catheter versus an irrigated tip catheter was associated with similar success rates, procedure duration, and fluoroscopic exposure. The technical complexity of the cooled tip catheter renders it less competitiveKeywords
This publication has 8 references indexed in Scilit:
- Prospective Randomized Comparison of Irrigated-Tip Versus Conventional-Tip Catheters for Ablation of Common FlutterCirculation, 2000
- Is 8-mm More Effective Than 4-mm Tip Electrode Catheter for Ablation of Typical Atrial Flutter?Circulation, 1999
- Atrial flutter: contemporary electrophysiology and catheter ablation.Pacing and Clinical Electrophysiology, 1999
- Role of the Tricuspid Annulus and the Eustachian Valve/Ridge on Atrial FlutterCirculation, 1996
- Radiofrequency Catheter Ablation of Type 1 Atrial FlutterCirculation, 1995
- Comparison of In Vivo Tissue Temperature Profile and Lesion Geometry for Radiofrequency Ablation With a Saline-Irrigated Electrode Versus Temperature Control in a Canine Thigh Muscle PreparationCirculation, 1995
- Radiofrequency ablation of the inferior vena cava-tricuspid valve isthmus in common atrial flutterPublished by Elsevier ,1993
- Radiofrequency catheter ablation for the treatment of human type 1 atrial flutter. Identification of a critical zone in the reentrant circuit by endocardial mapping techniques.Circulation, 1992