Effect of Ventricular Dilatation on Defibrillation Threshold in the Isolated Perfused Rabbit Heart
- 1 September 1997
- journal article
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 8 (9) , 1013-1019
- https://doi.org/10.1111/j.1540-8167.1997.tb00625.x
Abstract
Ventricular Dilatation and DFT. Introduction: Ventricular dilatation has Important electrophysiologic effects, but its effect on ventricular defibrillation threshold (DFT) is unknown. Methods and Results: A fluid-filled, latex balloon was placed in the left ventricular cavity of 19 isolated rabbit hearts. In each experiment, an undilated volume (equivalent to a left ventricular end-diastolic pressure of approximately 0 mmHg) was compared to a dilated volume achieved by adding 1.0 mL of saline (n = 10) or 5% dextrose (n = 9) to the intracavitary balloon. Left ventricular effective refractory period (ERP) and DFT were determined at each volume. Defibrillation was attempted with a monophasic shock delivered between a patch electrode positioned over the posterior left ventricle (cathode) and a metallic aortic cannula (anode). DFT was determined using a modified “down/up” protocol with 10-V steps. Ventricular dilatation increased the left ventricular end-diastolic pressure from 0 ± 0.5 mmHg to 35 ± 3 mmHg (P < 0.001), decreased the average left ventricular ERP 15% (from 116 ± 3 msec to 99 ± 3 msec; P < 0.001), and increased the average DFT 30% (from 96 ± 4 V to 125 ± 7 V; P < 0.001). In one third of experiments, the dilated DFT was ≥ 150% of the DFT at zero volume. The mechanism of the observed increase in DFT is unknown but may be related to the decrease in refractoriness observed with ventricular dilatation. Conclusion: Acute ventricular dilatation in this model increased DFT an average of 30%, an effect not previously described. This observation may have implications for patients with implantable cardioverter defibrillators.Keywords
This publication has 30 references indexed in Scilit:
- 960-88 Factors Associated with High Impedance with a Non-Thoracotomy Defibrillation Lead SystemJournal of the American College of Cardiology, 1995
- 927-38 Noninvasive Predictors of Successful Implantation of Transvenous Defibrillator Lead SystemsJournal of the American College of Cardiology, 1995
- 767-1 Determinants of Defibrillation Energy Requirements in Heart FailureJournal of the American College of Cardiology, 1995
- Pronounced increase in defibrillation threshold associated with pacing-induced cardiomyopathy in the dogAmerican Heart Journal, 1994
- Monophasic action potentials at discontinuation of cardiopulmonary bypass: evidence for contraction-excitation feedback in man.Circulation, 1988
- Electrophysiological effects of acute ventricular dilatation in the isolated rabbit heart.Circulation Research, 1988
- Changes in myocardial repolarization in patients undergoing balloon valvuloplasty for congenital pulmonary stenosis: evidence for contraction-excitation feedback in humans.Circulation, 1988
- Experimental congestive heart failure produced by rapid ventricular pacing in the dog: cardiac effects.Circulation, 1987
- Mechanically dependent changes in action potentials recorded from the intact frog ventricle.Circulation Research, 1978
- Termination of ventricular fibrillation in dogs by depolarizing a critical amount of myocardiumThe American Journal of Cardiology, 1975