An Electromechanical Spinal Injury Technique with Dynamic Sensitivity
- 1 January 1992
- journal article
- research article
- Published by Mary Ann Liebert Inc in Journal of Neurotrauma
- Vol. 9 (3) , 187-195
- https://doi.org/10.1089/neu.1992.9.187
Abstract
Over the past decade, our laboratory has attempted to create a simple, accurate device that could be used to produce reliable and quantifiable spinal cord injuries in the rodent. We report here on our latest of several modifications of a spinal cord impactor that has allowed us to meet these design criteria. The impactor uses the dynamic capacity of an electromagnetic driver (Ling shaker) and a unique pattern generator to briefly compress the dorsal surface of the spinal cord at velocities that may mimic compression injuries seen in the human. Calibrated, independent transducer systems provide open-loop output of the precise movement (displacement) of the impactor probe and the force necessary to achieve a given displacement. Touch sensitivity is accomplished by vibrating the probe slightly as it approaches the dural surface. This also allows a known biomechanical starting point. This combination of improvements in sensitivity and ability to measure all componenets of the dynamic compression has allowed us to determine detailed biomechanical descriptors of these impact injuries with low coefficients of variation. Furthermore, such descriptors correlate highly with histopathologic and behavioral outcome measures in animal populations with a variety of injury severities.Keywords
This publication has 15 references indexed in Scilit:
- NIH Workshop on Experimental Spinal Cord Injury: Modeling and CriteriaJournal of Neurotrauma, 1992
- Effect of Delayed Administration of U74006F (Tirilazad Mesylate) on Recovery of Locomotor Function After Experimental Spinal Cord InjuryJournal of Neurotrauma, 1991
- Three-Dimensional Computer-Assisted Analysis of Graded Contusion Lesions in the Spinal Cord of the RatJournal of Neurotrauma, 1991
- Interaction of Contact Velocity and Cord Compression in Determining the Severity of Spinal Cord InjuryJournal of Neurotrauma, 1988
- Electromechanical impactor for producing experimental spinal cord injury in animalsMedical & Biological Engineering & Computing, 1987
- A behavioral and anatomical analysis of spinal cord injury produced by a feedback-controlled impaction deviceExperimental Neurology, 1987
- An inexpensive apparatus for producing graded spinal cord contusive injury in the ratExperimental Neurology, 1987
- A reproducible spinal cord injury model in the catJournal of Neurosurgery, 1983
- Analysis and measurement of some sources of variability in experimental spinal cord traumaJournal of Neurosurgery, 1979
- Possible mechanisms for observed pathophysiological variability in experimental spinal cord injury by the method of AllenJournal of Neurosurgery, 1976