A comparison of sonographic cervical parameters in predicting spontaneous preterm birth in high‐risk singleton gestations
- 1 September 2001
- journal article
- research article
- Published by Wiley in Ultrasound in Obstetrics & Gynecology
- Vol. 18 (3) , 204-210
- https://doi.org/10.1046/j.0960-7692.2001.00526.x
Abstract
To assess the role of cervical sonography and to compare various sonographic cervical parameters in their ability to predict spontaneous preterm birth in high-risk singleton gestations. A prospective cohort of 469 high-risk gestations were longitudinally evaluated between 15 and 24 weeks' gestation on 1265 occasions with transvaginal cervical sonography and transfundal pressure. The cervical parameters obtained were funnel width and length, cervical length, percent funneling and cervical index. The information obtained was used for patient management. Restriction of physical activities was initiated at cervical lengths of ≤ 2.5 cm with cerclage as an option for cervical lengths of ≤ 2.0 cm. Receiver operating characteristic curve analyses showed that a cervical length of ≤ 2.5 cm between 15 and 24 weeks' gestation was equal to the other sonographic cervical parameters in its ability to predict spontaneous preterm birth. The sensitivities for delivery at < 28, < 30, < 32 and < 34 weeks' gestation were 94%, 91%, 83% and 76%, respectively, while the negative predictive values were 99%, 99%, 98% and 96%, respectively. The placement of a cerclage did not influence the positive and negative predictive values. In comparison to women with other risk factors, cervical length was best in the prediction of preterm birth in women with a prior mid-trimester loss; an optimal cut-off of ≤ 1.5 cm had sensitivities for delivery at < 28, < 30, < 32 and < 34 weeks' gestation of 100%, 100% 92% and 81%, respectively. The rate of preterm delivery at < 34 weeks' gestation increased dramatically when the cervical length was ≤ 1.5 cm. Cervical length was the only independent variable that entered the logistic regression model for the prediction of preterm delivery at < 34 weeks' gestation. In high-risk singleton gestations a cervical length of ≤ 2.5 cm was equal to other sonographic cervical parameters in its ability to predict spontaneous preterm birth and was better for the prediction of earlier forms of prematurity (at < 28 and < 30 weeks) than later forms (at < 32 and < 34 weeks). The optimal cervical lengths and their performance for predicting prematurity may be influenced by obstetric risk factors. Copyright © 2001 International Society of Ultrasound in Obstetrics and GynecologyKeywords
This publication has 22 references indexed in Scilit:
- Patients with an ultrasonographic cervical length ≤15 mm have nearly a 50% risk of early spontaneous preterm deliveryAmerican Journal of Obstetrics and Gynecology, 2000
- Second-trimester cervical ultrasound: associations with increased risk for recurrent early spontaneous deliveryPublished by Wolters Kluwer Health ,2000
- The relationship between placental histology and cervical ultrasonography in women at risk for pregnancy loss and spontaneous preterm birthAmerican Journal of Obstetrics and Gynecology, 1999
- Prediction of preterm delivery with transvaginal ultrasonography of the cervix in patients with high-risk pregnancies: Does cerclage prevent prematurity?American Journal of Obstetrics and Gynecology, 1999
- Cervical length at 23 weeks of gestation: prediction of spontaneous preterm deliveryUltrasound in Obstetrics & Gynecology, 1998
- Relationship between endocervical canal length between 15–24 weeks gestation and obstetric historyThe Journal of Maternal-Fetal Medicine, 1998
- Cervical ultrasonography compared with manual examination as a predictor of preterm deliveryAmerican Journal of Obstetrics and Gynecology, 1997
- Cervical funneling: sonographic criteria predictive of preterm deliveryUltrasound in Obstetrics & Gynecology, 1997
- The Length of the Cervix and the Risk of Spontaneous Premature DeliveryNew England Journal of Medicine, 1996
- Ultrasonographic examination of the uterine cervix is better than cervical digital examination as a predictor of the likelihood of premature delivery in patients with preterm labor and intact membranesAmerican Journal of Obstetrics and Gynecology, 1994