Minimal-volume excision of nonpalpable breast lesions
- 1 November 1989
- journal article
- research article
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 153 (5) , 957-961
- https://doi.org/10.2214/ajr.153.5.957
Abstract
To explore the value of accurate preoperative localization of occult breast lesions, we reviewed 100 consecutive needle-directed breast biopsies performed by the same surgeon over a 1-year period. A spring hookwire device for localization was inserted parallel to the chest wall. Two thirds of biopsies were performed under local anesthesia, and all were performed in an outpatient setting. Sixteen lesions were invasive carcinomas, and eight were ductal carcinomas in situ. In 96 lesions, the localizing wire was placed within 2 mm of the lesion, and in the remaining four it was within 5 mm of the abnormality. The mammographic lesion was excised in the first specimen in 96 cases. One patient required a second biopsy because of failure to excise the lesion in question after three specimens were taken. The only surgical complication was one hematoma, which resolved within 3 months. Median specimen volume for the entire series was 6.0 cm3. Median largest specimen diameter was 2.5 cm. Precise preoperative localization with a spring hookwire to within 2 mm of the mammographic lesion allows the surgeon to excise a median volume of 6 cm3 breast tissue with consistent retrieval of the lesion.This publication has 8 references indexed in Scilit:
- Analysis of Breast Cancer Mortality and Stage Distribution by Age for the Health Insurance Plan Clinical TrialJNCI Journal of the National Cancer Institute, 1988
- Localization and Excision of Nonpalpable Breast LesionsArchives of Surgery, 1987
- NEEDLE LOCALIZATION AND BIOPSY OF NONPALPABLE LESIONS OF THE BREAST1987
- Hooked-wire-directed breast biopsy and overpenetrated mammographyCancer, 1987
- Clinically occult breast lesions: localization and significance.Radiology, 1987
- Spring hookwire breast lesion localizer: use with rigid-compression mammographic systems.Radiology, 1985
- REDUCTION IN MORTALITY FROM BREAST CANCER AFTER MASS SCREENING WITH MAMMOGRAPHYThe Lancet, 1985
- Occult breast abnormalities: percutaneous preoperative needle localization.Radiology, 1984