Measurement of plasma D-dimer is not useful in the prediction or diagnosis of postoperative deep vein thrombosis in patients undergoing total knee arthroplasty
- 1 November 1998
- journal article
- clinical trial
- Published by Wolters Kluwer Health in Blood Coagulation & Fibrinolysis
- Vol. 9 (8) , 749-752
- https://doi.org/10.1097/00001721-199811000-00004
Abstract
Plasma D-dimer, a highly sensitive marker of venous thromboembolism, was measured using an enzyme-linked immunosorbent assay pre-operatively, on the third postoperative day, and at the time of phlebography in 118 patients undergoing elective total knee arthroplasty. Deep venous thrombosis (DVT) was detected using systematic bilateral phlebography between the eighth and 12th postoperative day in 47 (39.8%) patients. D-dimer plasma concentrations did not differ between patients who had DVT and those who had no DVT, either pre-operatively (n = 118, P = 0.63) or at the time of phlebography (n = 111, P = 0.70). On the third postoperative day, D-dimer concentration was significantly higher (P nKeywords