Mechanisms of chloride interferences in atomic absorption spectrometry using a graphite furnace atomizer investigated by electrothermal vaporization inductively coupled plasma mass spectrometry. Part 1. Effect of magnesium chloride matrix and ascorbic acid chemical modifier on manganese
- 1 January 1992
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 7 (2) , 371-381
- https://doi.org/10.1039/ja9920700371
Abstract
The interference by magnesium chloride with the atomization of manganese in electrothermal atomic absorption spectrometry (ETAAS) has been investigated using electrothermal vaporization inductively coupled plasma mass spectrometry (ETV-ICP-MS). The ETV-ICP-MS allows the direct observation of the loss of manganese during the charring step, and thereby allows differentiation between the manganese loss during charring and the loss due to formation of molecular species during atomization. The mechanism of interference by magnesium chloride is dependent on the charring temperature. At temperatures above 700 °C, the manganese is lost during charring; this loss occurs as the magnesium chloride matrix undergoes hydrolytic decomposition, and the manganese is carried away from the graphite furnace with the hydrogen chloride gas generated by the hydrolysis reaction. At charring temperatures lower than 700 °C the suppression in the manganese atomic absorption signal is due to a vapour-phase interference caused by formation of manganese chloride during atomization. The addition of ascorbic acid, as a chemical modifier, removes interferences in both the higher and the lower charring temperature regions. The results obtained by ETV-ICP-MS show that, for charring temperatures above 700 °C, ascorbic acid prevents the loss of manganese during charring. This effect is explained by retardation of hydrolysis of the magnesium chloride matrix by the chemical modifier, ascorbic acid.Keywords
This publication has 29 references indexed in Scilit:
- La matrice eau de mer et le signal du cuivre en spectrometrie d'adsorption atomique sans flammeAnalytica Chimica Acta, 1987
- Investigations of interferences in graphite furnace atomic absorption spectrometry using a dual-cavity platform. Part 2. Influence of sodium chloride and nickel chloride on the atomisation of leadJournal of Analytical Atomic Spectrometry, 1987
- Determination of lead by graphite furnace atomic absorption spectrometry with argon-hydrogen as the purge gas using low-temperature atomisationJournal of Analytical Atomic Spectrometry, 1986
- Chloride interferences in graphite furnace atomic absorption spectrometryAnalytical Chemistry, 1984
- Time and spatial absorbance profiles within a graphite furnace atomizerSpectrochimica Acta Part B: Atomic Spectroscopy, 1982
- Determination of iron, manganese, and zinc in seawater by graphite furnace atomic absorption spectrometryAnalytical Chemistry, 1979
- Comparison of Interference Effects for Manganese in Constant Temperature vs Pulse-Type Electrothermal AtomizationApplied Spectroscopy, 1979
- Electrothermal atomization—the way toward absolute methods of atomic absorption analysisSpectrochimica Acta Part B: Atomic Spectroscopy, 1978
- Interference of salt matrices in the determination of copper by atomic absorption spectrometry with electrothermal atomizationAnalytical Chemistry, 1978
- Investigations of reactions involved in flameless atomic absorption procedures : Part I. Application of high-temperature equilibrium calculations to a multicomponent system with special reference to the interference from chlorine in the flameless atomic absorption method for lead in steelAnalytica Chimica Acta, 1976