Reduced platelet activation and thrombosis in extracorporeal circuits coated with nitric oxide release polymers
- 1 April 2000
- journal article
- research article
- Published by Wolters Kluwer Health in Critical Care Medicine
- Vol. 28 (4) , 915-920
- https://doi.org/10.1097/00003246-200004000-00001
Abstract
To determine whether the use of nitric oxide (NO)-releasing polymers coated onto the inner surface of extracorporeal circuits can reduce platelet consumption and activation in the absence of systemic heparinization using a rabbit model of venovenous extracorporeal circulation. Prospective, controlled trial. Research laboratory at an academic medical institution. New Zealand White Rabbits. Anesthetized, tracheotomized, and ventilated New Zealand White rabbits were injected with freshly prepared, 111In(oxine)3 labeled single donor platelets through the external jugular vein. After baseline measurements, these animals were placed on venovenous extracorporeal circulation through a 1-m control circuit or NO test circuit for 4 hrs at a blood flow rate of 109-118 mL/min via roller pump. Four groups were studied: systemically heparinized control circuits, systemically heparinized NO test circuits, nonheparinized control circuits, and nonheparinized NO test circuits. Platelet counts, fibrinogen levels, and plasma free indium levels were measured hourly. Circuits were rinsed and retained for gamma counting after the 4-hr run or when the circuit clotted. Four animals, one from each group, did not receive radiolabeled platelets so that the circuits could be preserved for scanning electron microscopic examination after the 4-hr study. Platelet consumption was significantly reduced in both the heparinized and nonheparinized NO test groups when compared with the controls (p < .0001 and p < .0004, respectively). Platelet adhesion to the extracorporeal circuits was significantly reduced in the nonheparinized test circuits when compared with the controls (p < .05). Scanning electron microscopic examination of the circuits revealed that in the absence of heparin and in the presence of a NO-releasing surface, platelets retained their spherical nonactivated shape. The incorporation of NO into the surface of extracorporeal circuits reduces platelet consumption and eliminates the need for systemic heparinization in a rabbit model of extracorporeal circulation.Keywords
This publication has 14 references indexed in Scilit:
- Thromboresistant Chemical Sensors Using Combined Nitric Oxide Release/Ion Sensing Polymeric FilmsJournal of the American Chemical Society, 1997
- LetterThe Journal of Thoracic and Cardiovascular Surgery, 1996
- Nitric Oxide-Releasing Polymers Containing the [N(O)NO]-GroupJournal of Medicinal Chemistry, 1996
- Effect of extracorporeal membrane oxygenation on platelets in newbornsCritical Care Medicine, 1993
- The Biological and Pharmacological Role of Nitric Oxide in Platelet FunctionPublished by Springer Nature ,1993
- Nitric oxide functions as an inhibitor of platelet adhesion under flow conditions.Circulation, 1992
- Platelet consumption during neonatal extracorporeal life support (ECLS)Perfusion, 1992
- Relationship between prostacyclin and nitric oxide in the thrombotic processThrombosis Research, 1990
- The anti‐aggregating properties of vascular endothelium: interactions between prostacyclin and nitric oxideBritish Journal of Pharmacology, 1987
- Indium-111 labeled platelets: Studies on preparation and evaluation of in vitro and in vivo functionsThrombosis Research, 1976