Is Accurate Rate Response Programming Necessary?
- 1 August 1990
- journal article
- clinical trial
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 13 (8) , 1031-1044
- https://doi.org/10.1111/j.1540-8159.1990.tb02150.x
Abstract
Exercise capacity and general well-being are improved by appropriately programmed rate responsive pacemakers when compared to fixed rate units. Ten patients had activity sensing DDDR units implanted for combined AV block and sinus node incompetence. Ten patients had Sensolog activity sensing VVIR units implanted for complete heart block. The effects of over and under programming of rate response in both dual and single chamber activity sensor rate adaptive pacemakers has been assessed subjectively by visual analog scales and specific activity questionnaires and objectively by graded treadmill testing and the performance of standardized daily activities. Patients were randomly programmed to absent rate response (VVI in the Sensolog group), hyporesponsive (DDD in the dual chamber group), appropriate response (VVIR, DDDR according to Manufacturer's instructions) and over responsive (VVIR+, DDDR+) in a double-blind crossover design. Thirty percent of patients demanded early crossover from VVI, 30% from DDDR+ and 50% from VVIR+. Perception of Exercise Capability was similar to objective exercise treadmill times which were shorter in VVI than in VVIR or VVIR+ (P less than 0.05) or control subjects (P less than 0.001). There was no difference between any dual chamber mode or control subjects. General well-being was poorest in DDDR+ and VVIR+ modes despite objective improvement in exercise capacity. Symptoms were least in VVIR and DDDR and all but one patient chose appropriate programming as their overall preferred mode. Thus, even inaccurate rate response programming results in similar and improved exercise capacity compared to absent rate response but overprogramming is unacceptable to most patients, confirming that appropriate programming and sensor specificity is critical in rate responsive pacing.Keywords
This publication has 9 references indexed in Scilit:
- Comparison of exercise performance of six rate-adaptive right ventricular cardiac pacemakersThe American Journal of Cardiology, 1989
- Value of digital image processing of two-dimensional echocardiograms in differentiating active from chronic vegetations of infective endocarditis.Circulation, 1988
- Rate‐Responsive Pacing by Means of Activity Sensing Versus Single Rate Ventricular Pacing: A Double‐Blind Cross‐Over StudyPacing and Clinical Electrophysiology, 1987
- Rate‐Responsive Pacing: Biosensor Reliability and Physiological SensitivityPacing and Clinical Electrophysiology, 1987
- Increase in Cardiac Output with Rate-Responsive PacemakerThe Annals of Thoracic Surgery, 1986
- The Pacemaker SyndromeAnnals of Internal Medicine, 1985
- Physiological Versus Single-Rate Ventricular Pacing: A Double-Blind Cross-Over StudyPacing and Clinical Electrophysiology, 1985
- Comparative reproducibility and validity of systems for assessing cardiovascular functional class: advantages of a new specific activity scale.Circulation, 1981
- HAEMODYNAMIC EFFECT OF ATRIAL TRIGGERED VERSUS FIXED RATE PACING AT REST AND DURING EXERCISE IN COMPLETE HEART BLOCKActa Medica Scandinavica, 1975