Prediction of perinatal morbidity at term in small fetuses: comparison of fetal growth and Doppler ultrasound
- 1 May 1994
- journal article
- research article
- Published by Wiley in BJOG: An International Journal of Obstetrics and Gynaecology
- Vol. 101 (5) , 422-427
- https://doi.org/10.1111/j.1471-0528.1994.tb11916.x
Abstract
To compare fetal growth assessed by ultrasound (change in standard deviation score of abdominal circumference and estimated fetal weight) during the third trimester with predelivery ultrasound measurements of fetal size and Doppler measurements from the umbilical and fetal arteries in order to predict suboptimal perinatal outcome in small babies at term. Prospective observational study. Day assessment unit in a university hospital. One hundred and four consecutive women with a clinical suspicion of a small fetus during the third trimester confirmed by ultrasound (abdominal circumference below the 10th centile) and ultimately delivered at term. Acidaemia at birth, fetal distress requiring emergency caesarean section in labour, admission to the neonatal intensive care unit. Ninety-four babies (90%) weighed less than the 10th centile and the incidence of suboptimal perinatal outcome was 27%. The largest areas under the receiver operating characteristic curves for suboptimal perinatal outcome were obtained with the change in standard deviation score of abdominal circumference and estimated fetal weight, and the ratios of aortic/middle cerebral and renal/middle cerebral pulsatility index. Although low, the odds ratios of the change in estimated fetal weight standard deviation score and the Doppler ratios were significantly different from zero. Ultrasound assessment of fetal growth and predelivery fetal Doppler pulsatility index ratios were superior to predelivery estimates of fetal size and umbilical artery pulsatility index in predicting suboptimal perinatal outcome in small fetuses delivering at term, although the clinical value of such a prediction may be limited.Keywords
This publication has 29 references indexed in Scilit:
- An investigation of fetal growth using serial ultrasound dataUltrasound in Obstetrics & Gynecology, 1993
- Understanding the pathophysiology of intra-uterine growth retardation: the role of the ‘lower limb reflex’ in redistribution of blood flowEuropean Journal of Obstetrics & Gynecology and Reproductive Biology, 1992
- Comparison of the prognostic value of pulsed Doppler blood flow parameters to predict SGA and fetal distressUltrasound in Obstetrics & Gynecology, 1992
- Is obstetric and neonatal outcome worse in fetuses who fail to reach their own growth potential?BJOG: An International Journal of Obstetrics and Gynaecology, 1992
- Doppler measurements of fetal and uteroplacental circulations: Relationship with umbilical venous blood gases measured at cordocentesisAmerican Journal of Obstetrics and Gynecology, 1990
- Intrauterine growth retardation: Let's be clear about itBJOG: An International Journal of Obstetrics and Gynaecology, 1989
- A comparison of fetal abdominal circumference measurements and Doppler ultrasound in the prediction of small‐for‐dates babies and fetal compromiseBJOG: An International Journal of Obstetrics and Gynaecology, 1989
- Sonographic estimation of fetal weight and Doppler analysis of umbilical artery velocimetry in the prediction of intrauterine growth retardation: A prospective studyAmerican Journal of Obstetrics and Gynecology, 1988
- Estimation of fetal weight with the use of head, body, and femur measurements—A prospective studyPublished by Elsevier ,1985
- Percentiles for gas values in human umbilical cord bloodEuropean Journal of Obstetrics & Gynecology and Reproductive Biology, 1983