High Voltage Pulse Measuring System Based on Kerr Effect
- 1 March 1963
- journal article
- conference paper
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 34 (3) , 221-224
- https://doi.org/10.1063/1.1718316
Abstract
The voltage measuring system described in this current paper is based on the electro‐optical Kerr effect, viz, variations in the voltage magnitude will result in respective changes in the intensity of a light beam passing through the Kerr cell perpendicularly to the applied field. The proposed measuring system has the advantages of a fast response of the Kerr effect substance to the application of voltage transients‐better than 2×10−8 sec; and also high voltage pulses, with peak magnitude of the order of 105 V, may be applied directly across the cell. The complete separation of the measuring circuit from the pulse circuit eliminates the electric noise from reaching the measuring circuit without any screening of this circuit. However, its major limitation is that the recorded pulse has the ``rectified'' form of the original pulse waveform.Keywords
This publication has 3 references indexed in Scilit:
- High Voltage Measurement by ADP Crystal PlateReview of Scientific Instruments, 1956
- A Direct-Reading Oscilloscope for 100-KV PulsesProceedings of the IRE, 1953
- XL. A new relation between electricity and light: Dielectrified media birefringentJournal of Computers in Education, 1875