Field Comparison of P-Trak and Condensation Particle Counters
Open Access
- 1 July 2006
- journal article
- research article
- Published by Taylor & Francis in Aerosol Science and Technology
- Vol. 40 (6) , 422-430
- https://doi.org/10.1080/02786820600643321
Abstract
The P-trak ultrafine particle counter is a portable version of a condensation particle counter (CPC). Both instruments detect particle number concentrations in real time but have different detection limits. The P-trak has been widely used for indoor air quality evaluation and aerosol research. However, there is very limited information about the reliability and precision of this instrument and its comparability with other similar instruments. The purpose of this study was to compare a P-trak ultrafine particle counter with a standard CPC and evaluate its applicability to ambient air monitoring. This study was carried out near the Interstate 405 freeway (I-405) in Los Angeles. Measurements were made at increasing distances from the freeway on both sides at night as well as inside and outside of two 2-bedroom apartments located near the freeway. A CPC and a Scanning Mobility Particle Sizer (SMPS) were collocated with two P-traks and measurement results compared. In general, higher correlations were observed between P-trak and CPC data for indoor measurements than outdoor. The highest P-trak and CPC correlation ( r 2 = 0.9385) was detected inside Apartment 2, which is located farther away from the freeway than Apartment 1. The poorest correlation occurred at 30 m downwind from the freeway. In that case, the P-trak reported about 25% of ultrafine particle concentration that CPC did. A sigmoid (S-shape) function was fitted to observed P-trak to CPC ratios and geometric mean diameters of the corresponding ultrafine particle size distributions. Overall, we concluded the P-trak worked reasonably well when sampled indoor air. However, it has significant limitations in detecting freshly emitted ultrafine particles from vehicles. The P-trak underestimated ultrafine particles especially for particles smaller than its activation size which was found to be approximately 25–30 nm. Caution must be given in interpreting data collected by P-trak monitors near combustion sources.Keywords
This publication has 14 references indexed in Scilit:
- Penetration of freeway ultrafine particles into indoor environmentsJournal of Aerosol Science, 2004
- Personal Exposure to Submicrometer Particles and Heart Rate Variability in Human SubjectsEnvironmental Health Perspectives, 2004
- Measurement of Ultrafine Particles: A Comparison of Two Handheld Condensation Particle CountersAerosol Science and Technology, 2004
- Possible mechanisms of the cardiovascular effects of inhaled particles: systemic translocation and prothrombotic effectsToxicology Letters, 2004
- Study of ultrafine particles near a major highway with heavy-duty diesel trafficPublished by Elsevier ,2002
- Urban and rural ultrafine (PM0.1) particles in the Helsinki areaAtmospheric Environment, 2001
- Epidemiological evidence of the effects of ultrafine particle exposurePhilosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences, 2000
- MEASUREMENT OF TOTAL LUNG DEPOSITION OF INHALED ULTRAFINE PARTICLES IN HEALTHY MEN AND WOMENInhalation Toxicology, 2000
- Evaluation of the Measurement Performance of the Scanning Mobility Particle Sizer and Aerodynamic Particle SizerAerosol Science and Technology, 1999
- Engines and nanoparticlesJournal of Aerosol Science, 1998