Local organ dose conversion coefficients for angiographic examinations of coronary arteries
- 26 June 2007
- journal article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 52 (15) , 4393-4408
- https://doi.org/10.1088/0031-9155/52/15/003
Abstract
New organ dose conversion coefficients for coronary angiographic interventions are presented, as well as dose distributions and resulting maximal local dose conversion coefficients in the relevant organs. For the Monte Carlo based simulations, voxel models of the human anatomy were employed which represent the average Caucasian adult man and woman as defined by the International Commission on Radiological Protection. In the 21 investigated projections, the mean organ dose conversion coefficients vary from a few 0.01 to 2 mGy(Gy cm(2))(-1), depending on the projections. However, especially in portions of the lungs and the active bone marrow, the conversion coefficients can locally amount up to 10 mGy(Gy cm(2))(-1), which is half the average conversion coefficient of the skin at the field entrance. In addition to the dose conversion coefficients, the dependence of the patient dose on the projection has been estimated. It could be shown that the patient doses are highest for left anterior oblique views with strong caudal or cranial orientation. Nevertheless, for a large range of image-intensifier positions no significant dose differences could be found.Keywords
This publication has 23 references indexed in Scilit:
- PATIENT RADIATION EXPOSURE MEASUREMENTS DURING INTERVENTIONAL PROCEDURES: A PROSPECTIVE STUDYHealth Physics, 2006
- Comparison of effective doses obtained from dose–area product and air kerma measurements in interventional radiologyThe British Journal of Radiology, 2004
- Radiation Exposure to Patients Undergoing Percutaneous Coronary InterventionsHerz, 2004
- Effective techniques for reduction of radiation dosage to patients undergoing invasive cardiac proceduresThe British Journal of Radiology, 2003
- Radiation doses to patients undergoing coronary angiography and percutaneous tranluminal coronary angioplastyRadiation Protection Dosimetry, 2003
- Chronic radiodermatitis following cardiac catheterisation: a report of two cases and a brief review of the literatureHeart, 1999
- The impact of cardiology on the collective effective dose in the North of England.The British Journal of Radiology, 1997
- Effective doses for coronary angiographyThe British Journal of Radiology, 1996
- Radiation Risk and Exposure of Radiologists and Patients during Coronary Angiography and Percutaneous Transluminal Coronary Angioplasty (PTCA)Radiation Protection Dosimetry, 1995
- Effective dose ? how effective for patients?Radiation and Environmental Biophysics, 1993