Physiologic responses to exchange transfusion with hemoglobin vesicles as an artificial oxygen carrier in anesthetized rats
- 1 November 1996
- journal article
- Published by Wolters Kluwer Health in Critical Care Medicine
- Vol. 24 (11) , 1869-1873
- https://doi.org/10.1097/00003246-199611000-00017
Abstract
To evaluate the oxygen transporting capabilities of hemoglobin vesicles by studying the physiologic responses to exchange transfusion with hemoglobin vesicles in anesthetized rats. Exchange transfusions with phosphate buffered saline, hemoglobin vesicles containing methemoglobin (and therefore, deprived of oxygen transporting capabilities), and washed rat red blood cells were used as controls. Prospective, randomized, controlled trial. Department of Surgery, School of Medicine, Keio University. Twenty-seven male Wistar rats. The rats were anesthetized with an intraperitoneal injection of sodium pentobarbital (50 mg/kg). Catheters (PE-20 tubing, outer diameter 0.8 mm, inner diameter 0.5 mm) were introduced into the right jugular vein for infusion and the right common carotid artery for blood withdrawal and mean arterial pressure measurements. The left kidney was exposed by median abdominal incision, and a needle-type polarographic oxygen electrode was placed in the left renal cortex for renal cortical tissue oxygen tension measurements. Phosphate buffered saline and methemoglobin vesicles were administered as nonoxygen-carrying fluids, and rat red blood cells as oxygen-carrying fluid. Measurements included mean arterial pressure, arterial blood gas analysis, and renal cortical tissue oxygen tension as an indicator of systemic oxygen transport. In the rat red blood cell and hemoglobin vesicles groups, mean arterial pressure was sustained at the end of the exchange transfusion (82.3 +/- 27.5% and 73.5 +/- 11.5%, respectively, from the basal values). However, in the phosphate buffered saline and methemoglobin vesicles groups, mean arterial pressure decreased significantly (p < .05) (33.9 +/- 13.8% and 35.7 +/- 8.2%, respectively). Renal cortical tissue oxygen tension in the rat red blood cell and hemoglobin vesicles groups was sustained at a significantly higher level (p < .05) (83.5 +/- 9.3% and 75.0 +/- 11.9%, respectively) compared with the phosphate buffered saline and methemoglobin vesicles groups (44.9 +/- 12.8% and 58.3 +/- 6.2%, respectively) at the end of the exchange transfusion. Metabolic acidosis was more progressive in the phosphate buffered saline and methemoglobin vesicles groups, manifested as lower pH and base excess values. Platelet counts tended to decrease slightly in the hemoglobin vesicles and methemoglobin vesicles groups, but the changes were not significant. Hemoglobin vesicles have an oxygen transporting capability almost equivalent to rat red blood cells and can be considered as a potential artificial oxygen carrier.Keywords
This publication has 19 references indexed in Scilit:
- Physical Properties of Hemoglobin Vesicles as Red Cell SubstitutesBiotechnology Progress, 1996
- Novel Fluorocarbon-Based Injectable Oxygen-Carrying Formulations with Long-Term Room-Temperature Storage StabilityPublished by Springer Nature ,1994
- Circulation persistence and biodistribution of lyophilized liposome-encapsulated hemoglobin: An oxygen-carrying resuscitative fluidCritical Care Medicine, 1994
- Purification of Concentrated Hemoglobin Using Organic Solvent and Heat TreatmentProtein Expression and Purification, 1993
- A NEW SALUTARY RESUSCITATIVE FLUIDPublished by Wolters Kluwer Health ,1993
- Liposome-Encapsulated Hemoglobin: A Red Blood Cell SubstituteJournal of Liposome Research, 1993
- A human recombinant haemoglobin designed for use as a blood substituteNature, 1992
- Liposome-Encapsulated Hemoglobin: A Synthetic Red CellPublished by Springer Nature ,1988
- A kinetic study on functional impairment of nitric oxide-exposed rat erythrocytes.Environmental Health Perspectives, 1987
- Synthesis and Evaluation of a Prototypal Artificial Red CellScience, 1985