Capillary Electrochromatography of Proteins on an Anion-Exchanger Column
- 17 June 2000
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 72 (14) , 3022-3029
- https://doi.org/10.1021/ac000114t
Abstract
Capillary electrochromatography (CEC) of proteins was carried out using 50-μm-i.d. fused-silica capillaries packed with 5-μm silica beads having strong anion-exchanger functions attached to hydrophilic spacers at the chromatographic surface. The siliceous microspheres and the capillary innerwall were treated first with a heterobifunctional silanizing agent and reacted subsequently with a vinyl monomer containing quaternary ammonium groups to form a “tentacular” anion exchanger. A mixture of bovine carbonic anhydrase, α-lactalbumin, soybean trypsin inhibitor, and ovalbumin was separated using CEC by isocratic elution in the codirectional mode with aqueous phosphate buffer, pH 7.0, containing sodium chloride. The retention mechanism of isocratic CEC for proteins on the anion-exchanger column was illustrated by the results of a study on the effect of salt concentration on the separation. The potential of CEC for protein separation with high resolution was also demonstrated by electrochromatograms of conalbumin and hemoglobin variants. The results shed light on the mechanism of protein separation by isocratic CEC, which is believed to be a combination of chromatographic retention by electrostatic interactions and electrophoretic migration. Assuming that the contributions of the two mechanisms to the overall migration velocity are additive, an electrochromatographic resolution equation was derived and compared to the resolution equation in HPLC to reveal the constituents responsible for the enhancement of resolution by CEC with respect to that in HPLC. The advantage of CEC was also examined by comparing peak capacities in CEC on an isocratic platform with peak capacities obtained with isocratic and gradient elution HPLC.Keywords
This publication has 35 references indexed in Scilit:
- Dynamics of capillary electrochromatography experimental study on the electrosmotic flow and conductance in open and packed capillariesJournal of Chromatography A, 1997
- Some reflections on speed and efficiency of modern chromatographic methodsJournal of Chromatography A, 1997
- Capillary electrochromatography — a high-efficiency micro-separation techniqueJournal of Chromatography A, 1996
- Capillary Electrochromatography: Analysis of Polycyclic Aromatic HydrocarbonsAnalytical Chemistry, 1995
- Capillary electrochromatography — Some important considerations in the preparation of packed capillaries and the choice of mobile phase buffersChromatographia, 1995
- Terminology and nomenclature in capillary electroseparation systemsJournal of Chromatography A, 1994
- Electrochromatography and micro high-performance liquid chromatography with 320 μm I.D. packed columnsJournal of Chromatography A, 1994
- Electrokinetic reversed-phase chromatography with packed capillariesJournal of Chromatography A, 1992
- Electrochromatography in packed tubes using 1.5 to 50 μm silica gels and ODS bonded silica gelsChromatographia, 1991
- Electro-osmosisJournal of Chromatography A, 1974