Two commercial methods evaluated for eliminating the labile fraction from the assay for glycated hemoglobin (glycohemoglobin).

Abstract
Two recently introduced commercially available methods, a minicolumn and an electrophoresis assay, both effectively remove labile glycated hemoglobin generated in vitro and give results for patients' samples similar to those by liquid chromatography with samples pre-incubated in saline.

This publication has 0 references indexed in Scilit: