Calibration Methods for NIRS Instruments: A Theoretical Evaluation and Comparisons by Data Splitting and Simulations
- 1 March 1994
- journal article
- research article
- Published by SAGE Publications in Applied Spectroscopy
- Vol. 48 (3) , 327-332
- https://doi.org/10.1366/0003702944028335
Abstract
The properties of the recently proposed calibration method called restricted principal component regression (RPCR) were evaluated and compared with partial least-squares regression (PLSR) and two types of principal component regression (PCR1, selected according to the size of the eigenvalues, and PCR2, selected according to the t-value). RPCR can be considered a compromise between PCR and PLSR, since the first component of RPCR is equivalent to the first component of PLSR, while the rest can be regarded as principal components on a space orthogonal to the first. The methods showed almost the same properties when the irrelevant components had small eigenvalues. The prediction error of RPCR selected according to the size of the eigenvalues was intermediate to those of PCR1 and PLSR when the number of components was low, while RPCR and PCR1 nearly coincided when the number of components exceeded the number of relevant ones. The prediction error minimum was about the same for RPCR, PCR1, and PLSR, but the minimum of PLSR was obtained when a lower number of components were included in the calibration model.Keywords
This publication has 9 references indexed in Scilit:
- Prediction Error and Its Estimation for Subset-Selected ModelsTechnometrics, 1991
- On the Effect of Calibration and the Accuracy of NIR Spectroscopy with High Levels of Noise in the Reference ValuesApplied Spectroscopy, 1991
- Selection of Samples for Calibration in Near-Infrared Spectroscopy. Part II: Selection Based on Spectral MeasurementsApplied Spectroscopy, 1990
- Selection of Samples for Calibration in Near-Infrared Spectroscopy. Part I: General Principles Illustrated by ExampleApplied Spectroscopy, 1989
- Principal component regression in NIR analysis: Viewpoints, background details and selection of componentsJournal of Chemometrics, 1988
- Selection of optimal regression models via cross‐validationJournal of Chemometrics, 1988
- Comparison of Linear Statistical Methods for Calibration of NIR InstrumentsJournal of the Royal Statistical Society Series C: Applied Statistics, 1986
- Comparison of prediction methods for multicollinear dataCommunications in Statistics - Simulation and Computation, 1985
- A TWO‐STAGE TECHNIQUE FOR THE IN VITRO DIGESTION OF FORAGE CROPSGrass and Forage Science, 1963