Use of a Biocompatible Fiducial Marker in Evaluating the Accuracy of Computed Tomography Image Registration
- 1 October 1996
- journal article
- research article
- Published by Wolters Kluwer Health in Investigative Radiology
- Vol. 31 (10) , 658-667
- https://doi.org/10.1097/00004424-199610000-00008
Abstract
RATIONALE AND OBJECTIVES Accurate registration of computed tomography (CT) images to the patient is crucial for computer-assisted surgery. Markers used in roentgen stereo-grammetric analysis (RSA) can be located in a CT scan using a novel approach and also can be located physically. Roentgen stereo-grammetric analysis data act as “ground truth” for the three-dimensional marker locations. METHODS Two foam-bone phantoms were marked. The markers were scanned seven times with RSA, three times with axial CT, and contacted four times with a coordinate measuring arm. Root-mean-square (RMS) errors were derived for the registrations. RESULTS Computed tomography and RSA data register to 0.15 mm RMS error. Computed tomography and arm data register to 0.25 mm. The markers are biocompatible, and the coordinate measuring arm is usable in an operating room. CONCLUSIONS Typical in vitro registration errors are approximately 2 mm. The authors have developed a marker that provides superior registration, and a procedure that can be used for in vivo studies.Keywords
This publication has 28 references indexed in Scilit:
- Posterior cruciate function following total knee arthroplasty: A biomechanical studyThe Journal of Arthroplasty, 1994
- Micromotion of femoral stems in total hip arthroplasty. A randomized study of cemented, hydroxyapatite-coated, and porous-coated stems with roentgen stereophotogrammetric analysis.Journal of Bone and Joint Surgery, 1994
- A note on some identification problems arising in roentgen stereo photogrammetric analysisJournal of Biomechanics, 1994
- An image-directed robotic system for precise orthopaedic surgeryIEEE Transactions on Robotics and Automation, 1994
- Migration of porous coated acetabular prostheses fixed with screws: Roentgen stereophotogrammetric analysisJournal of Orthopaedic Research, 1992
- A method for registration of 3-D shapesIEEE Transactions on Pattern Analysis and Machine Intelligence, 1992
- Prediction of total knee motion using a three-dimensional computer-graphics modelJournal of Biomechanics, 1990
- Roentgen stereophotogrammetryActa Orthopaedica, 1989
- A robot with improved absolute positioning accuracy for CT guided stereotactic brain surgeryIEEE Transactions on Biomedical Engineering, 1988
- Extra-abdominal desmoid tumorsActa Orthopaedica, 1986