Limitations of the zero crossing detector in the analysis of intracoronary doppler: A comparison with fast fourier transform analysis of basal, hyperemic, and transstenotic blood flow velocity measurements in patients with coronary artery disease
- 1 January 1993
- journal article
- research article
- Published by Wiley in Catheterization and Cardiovascular Diagnosis
- Vol. 28 (1) , 56-64
- https://doi.org/10.1002/ccd.1810280112
Abstract
The current clinical standard for the analysis of intracoronary Doppler signals is the application of a zero‐crossing (ZC) detector. However, the accuracy of the method is questionable, especially in areas of disturbed flow, as confirmed by in vitro studies, animal experiments, and intraoperative observations. The aim of this study is the comparison of a conventional ZC detector and a custom‐designed spectral analyzer (fast Fourier transform, FFT) in the analysis of intracoronary Doppler signals obtained in 19 patients undergoing coronary angioplasty. A 3F catheter with an end‐mounted Doppler ceramic crystal was placed over an 0.014″ guidewire in a normal or near‐normal segment proximal to the lesion to be dilated. The Doppler signal was recorded before and after intracoronary infusion of 12.5 mg of papaverine. In 9 patients high flow velocities could be recorded when the catheter was advanced across the stenosis. The blood flow velocity measurements obtained with ZC were significantly lower than the maximal FFT flow velocity measurements (16±12 cm/s vs. 29±18 cm/s, p < .001). In all the conditions of Doppler signal acquisition (baseline, hyperemia, stenosis) a large scattering of the signed differences between corresponding measurements was observed. The standard deviation of the difference ZC‐FFT was ±11 cm/s and ±5 cm/s for the maximal and mean FFT flow velocity, corresponding in both cases to ±37% of the mean of the ZC and FFT measurements. Large differences were also observed in the values of coronary flow reserve (CFR) calculated as the ratio between ZC and FFT flow velocity measurements 30 s after papaverine intracoronary and at baseline. The standard deviation of the difference ZC‐FFT based CFR was ±1.3 and ±1.2 for the values derived from the maximal and mean FFT flow velocities (percent difference ±32% and ±37%, respectively). In conclusion, the measurements obtained from the same intracoronary Doppler signal analyzed with a ZC detector and an FFT technique showed large differences in various conditions of flow and also in the assessment of relative flow velocity derived indices such as CFR. Spectral analysis should replace the current use of a ZC detector for the evaluation of coronary Doppler signals, even for the assessment of relative flow velocity changes.Keywords
This publication has 15 references indexed in Scilit:
- Endothelial dysfunction of the coronary microvasculature is associated with coronary blood flow regulation in patients with early atherosclerosis.Circulation, 1991
- Divergent Effects of Serotonin on Coronary-Artery Dimensions and Blood Flow in Patients with Coronary Atherosclerosis and Control PatientsNew England Journal of Medicine, 1991
- Effects of adenosine on human coronary arterial circulation.Circulation, 1990
- Assessment of severity of coronary stenoses using a Doppler catheter. Validation of a method based on the continuity equation.Circulation, 1989
- Value and limitations of intracoronary adenosine for the assessment of coronary flow reserveCatheterization and Cardiovascular Diagnosis, 1988
- Subselective measurement of coronary blood flow velocity using a steerable doppler catheterJournal of the American College of Cardiology, 1986
- Intracoronary papaverine: an ideal coronary vasodilator for studies of the coronary circulation in conscious humans.Circulation, 1986
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986
- Transluminal, subselective measurement of coronary artery blood flow velocity and vasodilator reserve in man.Circulation, 1985
- Accuracy and limitations of the ultrasonic Doppler blood velocimeter and zero crossing detectorUltrasound in Medicine & Biology, 1975