Lung Mechanics and Gas Exchange during Pressure-Control Ventilation in Dogs: Augmentation of CO2Elimination by an Intratracheal Catheter
- 1 October 1992
- journal article
- Published by American Thoracic Society in American Review of Respiratory Disease
- Vol. 146 (4) , 965-973
- https://doi.org/10.1164/ajrccm/146.4.965
Abstract
Increased awareness of pressure-related injury to the alveolar-capillary interface has renewed interest in modes of ventilation that limit alveolar distention such as pressure-controlled ventilation (PCV). We examined respiratory system mechanics and gas exchange during PCV in six dogs. Our data conformed to the predictions of our single-compartment mathematical model of respiratory dynamics during PCV (J Appl Physiol 1989; 67:1081-92). For a fixed pressure (Pset) and inspiratory time fraction (Tl/Ttot) (15 cm H2O and 0.3, respectively), minute ventilation (VE) reached a well-defined plateau as frequency (f) increased from 10 to 50 breaths/min and tidal volume (VT) fell progressively. Concomitantly, the physiologic dead-space fraction (VD/VT) increased from 0.50 +/- 0.04 to 0.85 +/- 0.04, and arterial PCO2 (PaCO2) rose from 39 +/- 4 to 76 +/- 12 mm Hg. At a fixed combination of frequency, applied pressure, and Tl/Ttot (40 breaths/min, 15 cm H2O, and 0.3), VE did not change when we introduced fresh gas continuously from an intratracheal catheter. However, PaCO2 and VD/VT fell progressively as catheter flow increased from zero to 14 L/min (60 +/- 12 to 40 +/- 12 mm Hg and 0.83 +/- 0.03 to 0.25 +/- 0.14 mm Hg, respectively). We conclude that during PCV at a fixed Pset and Tl/Ttot increasing frequency caused VT to fall and VE to reach a plateau. Declining VT was associated with a rise in PaCO2 because of a subsequent fall in alveolar ventilation. Insufflating fresh gas by an intratracheal catheter increased alveolar ventilation and improved CO2 elimination by washing out the anatomic dead space.(ABSTRACT TRUNCATED AT 250 WORDS)Keywords
This publication has 8 references indexed in Scilit:
- Airway Insufflation: Increasing Flow Rates Progressively Reduce Dead Space in Respiratory FailureAmerican Review of Respiratory Disease, 1991
- Cardiorespiratory Effects of Pressure Controlled Ventilation in Severe Respiratory FailureChest, 1990
- Low mortality associated with low volume pressure limited ventilation with permissive hypercapnia in severe adult respiratory distress syndromeIntensive Care Medicine, 1990
- Pressure Control Inverse Ratio Ventilation as a Method to Reduce Peak Inspiratory Pressure and Provide Adequate Ventilation and OxygenationChest, 1989
- Evaluation of thoracic mechanics in the ventilated patient part II: Applied mechanicsJournal of Critical Care, 1988
- Gas Exchange during Constant Flow Ventilation with Different GasesAmerican Review of Respiratory Disease, 1987
- Ion range distributions in multilayered structures: Bi in Si/GeJournal of Applied Physics, 1987
- Interrupter technique for measurement of respiratory mechanics in anesthetized catsJournal of Applied Physiology, 1984