Electrode system influence on biphasic waveform defibrillation efficacy in humans.
- 1 August 1991
- journal article
- clinical trial
- Published by Wolters Kluwer Health in Circulation
- Vol. 84 (2) , 665-671
- https://doi.org/10.1161/01.cir.84.2.665
Abstract
BACKGROUND Several clinical studies have demonstrated a general superiority of biphasic waveform defibrillation compared with monophasic waveform defibrillation using epicardial lead systems. To test the breadth of utility of biphasic waveforms in humans, a prospective, randomized evaluation of defibrillation efficacy of monophasic and single capacitor biphasic waveform pulses was performed for two distinct nonthoracotomy lead systems as well as for an epicardial electrode system in 51 cardiac arrest survivors undergoing automatic defibrillator implantation. METHODS AND RESULTS The configurations tested consisted of a right ventricular-left ventricular (RV-LV) epicardial patch-patch system, an RV catheter-chest patch (CP) nonthoracotomy system, and a coronary sinus (CS) catheter-RV catheter nonthoracotomy system. For each configuration, the defibrillation current and voltage waveforms were recorded via a digital oscilloscope to measure defibrillation threshold voltage, current, resistance, and stored energy. Biphasic waveform defibrillation proved more efficient than monophasic waveform defibrillation for the epicardial RV-LV system (4.8 +/- 4.1 versus 6.7 +/- 4.9 J, p = 0.047) and the nonthoracotomy RV-CP system (23.4 +/- 11.1 versus 34.3 +/- 10.4 J, p = 0.0042). Biphasic waveform defibrillation thresholds were not significantly lower than monophasic waveform defibrillation thresholds for the CS-RV nonthoracotomy system (15.6 +/- 7.2 versus 20.0 +/- 11.5 J, p = 0.11). Biphasic waveform defibrillation proved more efficacious than monophasic waveform defibrillation in 13 of 20 patients (65%) with RV-LV epicardial patches, 10 of 15 patients (67%) with an RV-CP nonthoracotomy system, and nine of 16 patients (56%) with an RV-CS nonthoracotomy system. CONCLUSIONS Biphasic pulsing was useful with nonthoracotomy lead systems as well as with epicardial lead systems. However, the degree of biphasic waveform defibrillation superiority appeared to be electrode system dependent. Furthermore, for a few individuals, biphasic waveform defibrillation proved less efficient than monophasic waveform defibrillation, regardless of the lead system used.Keywords
This publication has 15 references indexed in Scilit:
- An effective and adaptable transvenous defibrillation system using the coronary sinus in humansJournal of the American College of Cardiology, 1990
- Electrophysiological Effects of Monophasic and Biphasic Stimuli in Normal and Infarcted DogsPacing and Clinical Electrophysiology, 1990
- A prospective randomized evaluation of biphasic versus monophasic waveform pulses on defibrillation efficacy in humansJournal of the American College of Cardiology, 1989
- Prospective comparison of sequential pulse and single pulse defibrillation with use of two different clinically available systemsJournal of the American College of Cardiology, 1989
- Evaluation of electrode polarity on defibrillation efficacyThe American Journal of Cardiology, 1989
- Improved internal defibrillation efficacy with a biphasic waveformAmerican Heart Journal, 1989
- Ventricular defibrillation using biphasic waveforms: The importance of phasic durationJournal of the American College of Cardiology, 1989
- Improved low energy defibrillation efficacy in man with the use of a biphasic truncated exponential waveformAmerican Heart Journal, 1989
- The frequency dependence of an analytical model of an electrically stimulated biological structureBioelectromagnetics, 1984
- Termination of ventricular fibrillation in dogs by depolarizing a critical amount of myocardiumThe American Journal of Cardiology, 1975