Determination of terbutaline enantiomers in biological samples using liquid chromatography with coupled columns
- 31 December 1988
- Vol. 1 (1) , 20-26
- https://doi.org/10.1002/chir.530010107
Abstract
The purpose of this work was to develop and validate a method for the separation and determination of the enantiomers of terbutaline in plasma and intestinal juice. Terbutaline was extracted from plasma and intestinal juice by liquid-solid extraction on small C18 cartridges. The extract was then analyzed by coupled column liquid chromatography with amperometric detecton. For ciral separation a β-cyclodextrin phase was used. The within-day variation (Cv) on spiked plasma samples was in the rane 0.8-6.4% at 3.8-33.8 nmol/liter for the (−)-enantiomer, and 2.6-23.0% at 1.3-11.3 nmol/liter for the (+)-enantiomer. The between-day variation on spiked plasma samples was 5.5% at 10.7 nmol/liter and 13.6% at 4.3 nmol/liter for the (−)- and (+)-enantiomers, respectively. The within-day variation for inestinal juice was i the range 0.7-1.5% at 5.6-30.0 μmol/liter for the (+)-enantiomer.Keywords
This publication has 9 references indexed in Scilit:
- Pharmacokinetic evaluation in man of terbutaline given as separate enantiomers and as the racemate.British Journal of Clinical Pharmacology, 1989
- Determination of drug enantiomers in biological samples by coupled column liquid chromatography and liquid chromatography-mass spectrometryJournal of Chromatography B: Biomedical Sciences and Applications, 1987
- Quantitative determination of terbutaline in human plasma after administration of bambuterol using coupled columns and electrochemical detectionChromatographia, 1987
- Optical Resolution of Some Mandelic Derivatives on a Chemically Bonded Cyclodextrin Stationary PhaseJournal of Liquid Chromatography, 1986
- Liquid chromatographic separation of enantiomers using a chiral .beta.-cyclodextrin-bonded stationary phase and conventional aqueous-organic mobile phasesAnalytical Chemistry, 1985
- Steric Aspects of Agonism and Antagonism at β‐Adrenoceptors: Experiments with the Enantiomers of Terbutaline and PindololActa Pharmacologica et Toxicologica, 1984
- Quantitative Analysis of Terbutaline (Bricanyl®) in Human Plasma with Liquid Chromatography and Electrochemical Detection Using On-Line EnrichmentJournal of Liquid Chromatography, 1983
- Automated analysis of terbutaline (BricanylR) in human plasma with liquid chromatography and electrochemical detection using column-switching (multidimensional chromatography)Chromatographia, 1982
- Determination of terbutaline in plasma by gas chromatography chemical ionization mass spectrometryJournal of Mass Spectrometry, 1980