T2 mapping from highly undersampled data by reconstruction of principal component coefficient maps using compressed sensing
Top Cited Papers
Open Access
- 16 August 2011
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 67 (5) , 1355-1366
- https://doi.org/10.1002/mrm.23128
Abstract
Recently, there has been an increased interest in quantitative MR parameters to improve diagnosis and treatment. Parameter mapping requires multiple images acquired with different timings usually resulting in long acquisition times. While acquisition time can be reduced by acquiring undersampled data, obtaining accurate estimates of parameters from undersampled data is a challenging problem, in particular for structures with high spatial frequency content. In this work, principal component analysis is combined with a model‐based algorithm to reconstruct maps of selected principal component coefficients from highly undersampled radial MRI data. This novel approach linearizes the cost function of the optimization problem yielding a more accurate and reliable estimation of MR parameter maps. The proposed algorithm—reconstruction of principal component coefficient maps using compressed sensing—is demonstrated in phantoms and in vivo and compared with two other algorithms previously developed for undersampled data. Magn Reson Med, 2012.Keywords
Funding Information
- NIH (HL085385)
This publication has 29 references indexed in Scilit:
- Quantitative mapping of T1 and T2* discloses nigral and brainstem pathology in early Parkinson's diseaseNeuroImage, 2010
- Rapid water and lipid imaging with T2 mapping using a radial IDEAL‐GRASE techniqueMagnetic Resonance in Medicine, 2009
- Interleaved T1 and T2 relaxation time mapping for cardiac applicationsJournal of Magnetic Resonance Imaging, 2009
- Sparse MRI: The application of compressed sensing for rapid MR imagingMagnetic Resonance in Medicine, 2007
- Imaging lung function using rapid dynamic acquisition of T 1-maps during oxygen enhancementMagnetic Resonance Materials in Physics, Biology and Medicine, 2004
- Quantitative T1 Mapping of Hepatic Encephalopathy Using Magnetic Resonance ImagingHepatology, 2003
- Nonuniform fast fourier transforms using min-max interpolationIEEE Transactions on Signal Processing, 2003
- Time‐resolved contrast‐enhanced imaging with isotropic resolution and broad coverage using an undersampled 3D projection trajectoryMagnetic Resonance in Medicine, 2002
- Radial fast spin‐echo method for T2‐weighted imaging and T2 mapping of the liverJournal of Magnetic Resonance Imaging, 2002
- Value of T1 and T2 relaxation times from echoplanar MR imaging in the characterization of focal hepatic lesions.American Journal of Roentgenology, 1993