The Stability of Radio-Frequency Plasma-Treated Polydimethylsiloxane Surfaces
- 6 February 2007
- journal article
- research article
- Published by American Chemical Society (ACS) in Langmuir
- Vol. 23 (6) , 3118-3122
- https://doi.org/10.1021/la0627720
Abstract
Polydimethylsiloxane (PDMS) is a widely used material for manufacturing lab-on-chip devices. However, the hydrophobic nature of PDMS is a disadvantage in microfluidic systems. To transform the hydrophobic PDMS surface to hydrophilic, it was treated with radio-frequency (RF) air plasma at 150, 300, and 500 mTorr pressures for up to 30 min. Following the surface treatment, the PDMS specimens were stored in air, deionized water, or 0.14 M NaCl solution at 4 °C, 20 °C, and 70 °C. The change in the hydrophilicity (wettability) of the PDMS surfaces was followed by contact angle measurements and Fourier transform infrared attenuated total reflectance (FTIR-ATR) spectroscopy as a function of time. As an effect of the RF plasma treatment, the contact angles measured on PDMS surfaces dropped from 113 ± 4° to 9 ± 3°. The chamber pressure and the treatment time had no or negligible effect on the results. However, the PDMS surface gradually lost its hydrophilic properties in time. The rate of this process is influenced by the difference in the dielectric constants of the PDMS and its ambient environment. It was the smallest at low temperatures in deionized water and largest at high temperatures in air. Apparently, the OH groups generated on the PDMS surface during the plasma treatment tended toward a more hydrophilic/less hydrophobic environment during the relaxation processes. The correlation between the FTIR-ATR spectral information and the contact angle data supports this interpretation.Keywords
This publication has 18 references indexed in Scilit:
- Thermal aging and reduced hydrophobic recovery of polydimethylsiloxaneSensors and Actuators B: Chemical, 2005
- Ultraviolet sealing and poly(dimethylacrylamide) modification for poly(dimethylsiloxane)/glass microchipsElectrophoresis, 2004
- Microfluidic devices fabricated in Poly(dimethylsiloxane) for biological studiesElectrophoresis, 2003
- Surface modification of poly(dimethylsiloxane) microchannelsElectrophoresis, 2003
- Surface characterization using chemical force microscopy and the flow performance of modified polydimethylsiloxane for microfluidic device applicationsElectrophoresis, 2003
- Hemocompatibility, biocompatibility, inflammatory and in vivo studies of primary reference materials low‐density polyethylene and polydimethylsiloxane: A reviewJournal of Biomedical Materials Research, 2001
- Real-Time Mid-IR Monitoring of the Initiation and Propagation in Epoxi-Initiated Living Isobutylene PolymerizationsMacromolecules, 2000
- A possible hydrodynamic origin of the forces of hydrophobic attractionJournal of Colloid and Interface Science, 1991
- On the aging of oxygen plasma-treated polydimethylsiloxane surfacesJournal of Colloid and Interface Science, 1990
- Polymer Surface DynamicsPublished by Springer Nature ,1985