Comparison of End-Tidal PCO2 and Average Alveolar Expired PCO2 During Positive End-Expiratory Pressure
- 1 February 1996
- journal article
- Published by Wolters Kluwer Health in Anesthesia & Analgesia
- Vol. 82 (2) , 368-373
- https://doi.org/10.1097/00000539-199602000-00027
Abstract
The measurement of average alveolar expired PCO2 (PAECO2) weights each PCO2 value on the alveolar plateau of the CO2 expirogram by the simultaneous change in exhaled volume. PAECO2 can be determined from a modified analysis of the Fowler anatomic dead space (VDANAT). In contrast, end-tidal PCO2 (PETCO2) only measures PCO2 in the last small volume of exhalate. In conditions such as mechanical ventilation with positive end-expiratory pressure (PEEP), where the alveolar plateau can have a significant positive slope, we questioned how much PETCO2 could overestimate PAECO2. Accordingly, in six anesthetized ventilated dogs, we digitally measured and processed tidal PCO2 and flow to determine VDANAT. We determined PETCO2 and PAECO before and after the application of 7.6 cm H2O PEEP. Alveolar dead space to tidal volume fraction (VD/VT) was determined by [arterial PCO2- alveolar PCO2]/arterial PCO2, where alveolar PCO2 was determined by either PETCO2 or PAECO2. During baseline ventilation, PETCO2 was 3.4 mm Hg (approximately 11%) greater than PAECO2. Because PEEP significantly increased the slope of the alveolar plateau from 28 to 74 mm Hg/L, the difference between PETCO2 and PAECO2 significantly increased to 6.6 mm Hg (approximately 20% difference). The concurrent increase in VDANAT during PEEP decreased alveolar tidal volume and tended to limit the overestimation of PETCO2 compared to PAECO2. When alveolar PCO2 was estimated by PETCO2, alveolar VD/VT was 18%, compared to an alveolar VD/VT of 26% when alveolar PCO2 was estimated by PAECO2. This difference was significantly magnified during PEEP ventilation. The overestimation of PAECO2 by PETCO2 can result in a falsely high assessment of overall alveolar PCO2. Moreover, the use of PETCO2 to estimate alveolar PCO2 in the determination of the alveolar dead space fraction can result in falsely low and even negative values of alveolar dead space.Keywords
This publication has 16 references indexed in Scilit:
- Capnometer Transport DelayAnesthesia & Analgesia, 1994
- Can Changes in End-Tidal Pco2 Measure Changes in Cardiac Output?Anesthesia & Analgesia, 1991
- Sensitivity of CO2 washout to changes in acinar structure in a single-path model of lung airwaysAnnals of Biomedical Engineering, 1991
- The arterial - end-tidal CO2 difference during cardiothoracic surgeryJournal of Cardiothoracic Anesthesia, 1990
- RELATIONSHIP BETWEEN ALVEOLAR DEADSPACE AND ARTERIAL OXYGENATION IN CHILDREN WITH CONGENITAL CARDIAC DISEASE †British Journal of Anaesthesia, 1989
- CAPNOGRAPHYInternational Anesthesiology Clinics, 1989
- Esophageal IntubationAnesthesia & Analgesia, 1986
- THE CONCEPT OF DEADSPACE WITH SPECIAL REFERENCE TO THE SINGLE BREATH TEST FOR CARBON DIOXIDEBritish Journal of Anaesthesia, 1981
- Dead Space at Rest and During ExerciseJournal of Applied Physiology, 1955
- LUNG FUNCTION STUDIES. II. THE RESPIRATORY DEAD SPACEAmerican Journal of Physiology-Legacy Content, 1948