Abstract
Object. The goal of this study was to assess the diagnostic accuracy of computerized tomography (CT) angiography performed with the aid of multislice technology (MSCT angiography) in the investigation of intracranial aneurysms, by comparing this method with intraarterial digital subtraction (IADS) angiography. Methods. Fifty consecutive adult patients, who successively underwent MSCT angiography (four rows) and IADS angiography of intracranial vessels, were prospectively identified. The MSCT angiography studies consisted of 1.25-mm slices, with 0.8-mm reconstruction intervals, a pitch of 0.75, and timing determined by a test bolus. Two neuroradiologists, who were blinded to the initial interpretation of the MSCT angiograms as well as to those of the IADS angiograms, independently reviewed the MSCT angiograms for the detection and characterization of intracranial aneurysms. Forty-nine intracranial aneurysms were identified in 40 patients; 33 of these lesions were responsible for subarachnoid hemorrhage. The sensitivity, specificity, and accuracy of MSCT angiography in the detection of intracranial aneurysms were 94.8, 95.2, and 94.9%, respectively, on a per-aneurysm basis and 99, 95.2, and 98.3%, respectively, on a per-patient basis. Interobserver agreement was 98%. There was an excellent correlation between aneurysm size assessed using MSCT angiography and that determined by IADS angiography (slope = 0.916, r = 0.877, p < 0.001); however, 2 mm stood as the cutoff size below which the sensitivity of MSCT angiography was statistically lower. That method displayed great accuracy in characterizing the morphological characteristics of the aneurysm. Conclusions. Multislice CT angiography is an accurate and robust noninvasive screening test for intracranial aneurysms. It performs better than that reported for single-slice CT angiography. Introduction of eight- and especially 16-row MSCT angiography will provide further progression through thinner slices, a lower pitch, and a purely arterial phase.Keywords
This publication has 37 references indexed in Scilit:
- What is the most sensitive non-invasive imaging strategy for the diagnosis of intracranial aneurysms?Journal of Neurology, Neurosurgery & Psychiatry, 2001
- Volume-rendered helical computerized tomography angiography in the detection and characterization of intracranial aneurysmsJournal of Neurosurgery, 2000
- Detection of intracranial aneurysms with unenhanced and echo contrast enhanced transcranial power DopplerJournal of Neurology, Neurosurgery & Psychiatry, 2000
- Risk of Cerebral Angiography in Patients With Subarachnoid Hemorrhage, Cerebral Aneurysm, and Arteriovenous MalformationStroke, 1999
- Spiral CT Scanning in the Detection and Evaluation of Aneurysms of the Circle of WillisSurgical Neurology, 1998
- Computerized tomography angiography in isolated third nerve palsiesJournal of Neurosurgery, 1998
- Three-dimensional volume rendering for magnetic resonance angiography in the screening and preoperative workup of intracranial aneurysmsJournal of Neurosurgery, 1996
- Patients with Polycystic Kidney Disease Would Benefit from Routine Magnetic Resonance Angiographic Screening for Intracerebral Aneurysms: A Decision AnalysisNeurosurgery, 1996
- Guidelines for the management of aneurysmal subarachnoid hemorrhage. A statement for healthcare professionals from a special writing group of the Stroke Council, American Heart Association.Stroke, 1994
- Relation of Cerebral Vasospasm to Subarachnoid Hemorrhage Visualized by Computerized Tomographic ScanningNeurosurgery, 1980