Biventricular Support With the Jarvik 2000 Ventricular Assist Device in a Calf Model of Pulmonary Hypertension
- 1 September 2004
- journal article
- research article
- Published by Wolters Kluwer Health in Asaio Journal
- Vol. 50 (5) , 444-450
- https://doi.org/10.1097/01.mat.0000139304.34821.f1
Abstract
The Jarvik 2000 ventricular assist device (VAD) is clinically efficacious for treating end-stage left ventricular failure. Because simultaneous right ventricular support is also occasionally necessary, we developed a biventricular Jarvik 2000 technique and tested it in a calf model. One VAD was implanted in the left ventricle with outflow-graft anastomosis to the descending aorta. The other VAD was implanted in the right ventricle with outflow-graft anastomosis to the pulmonary artery. Throughout the 30 day study, hemodynamic values were continuously monitored. On day 30, both pumps were evaluated at different speeds, under various hemodynamic conditions. By gradually occluding the pulmonary artery proximally or distally, we simulated varying degrees of high pulmonary vascular resistance, right ventricular hypertension, global heart failure, or ventricular fibrillation. The two VADs maintained biventricular support even during pulmonary artery occlusion and ventricular fibrillation, yielding a cardiac output of 3–11 L/min, left ventricular end-diastolic pressure of 11–24 mm Hg, and central venous pressure of 9–25 mm Hg. End-organ function was unimpaired, and no major adverse events occurred. The dual VADs offered safe, effective biventricular assistance in the calf. Additional studies are needed to assess the effects of lowered pulse pressure upon the pulmonary circulation and to develop a single pump speed controller.Keywords
This publication has 31 references indexed in Scilit:
- Use of the Jarvik 2000 Left Ventricular Assist System as a Bridge to Heart Transplantation or as Destination Therapy for Patients With Chronic Heart FailureAnnals of Surgery, 2003
- Circulatory Support for Long-Term Treatment of Heart FailureCirculation, 2002
- The effect of a systemic arteriovenous fistula on the pulmonary arterial blood pressure in the fetal sheepPrenatal Diagnosis, 2002
- PULMONARY MICROCIRCULATION DURING PULSATILE AND NONPULSATILE PERFUSIONSAsaio Journal, 1997
- Preoperative and postoperative comparison of patients with univentricular and biventricular support with the thoratec ventricular assist device as a bridge to cardiac transplantationThe Journal of Thoracic and Cardiovascular Surgery, 1997
- Importance of Metabolic Function of the Natural Lung Evaluated by Prolonged Exclusion of the Pulmonary CirculationAsaio Journal, 1996
- Experience with right ventricular assist devices for perioperative right-sided circulatory failureThe Annals of Thoracic Surgery, 1996
- ESTABLISHMENT OF CANINE PULMONARY HYPERTENSION WITH DEHYDROMONOCROTALINETransplantation, 1995
- Production and reversibility of right ventricular hypertrophy and right heart failure in dogsThe Annals of Thoracic Surgery, 1992
- Depression of Pulmonary Metabolic Function by Cardiopulmonary Bypass Procedures Increases Levels of Circulating NorepinephrineThe Annals of Thoracic Surgery, 1984