Indirekte Bestimmung des intrapulmonalen Druckverlaufes am Lungenmodell bei Hochfrequenzbeatmung
- 1 September 1989
- journal article
- research article
- Published by Springer Nature in Journal of Molecular Medicine
- Vol. 67 (18) , 946-950
- https://doi.org/10.1007/bf01721423
Abstract
One of the determinants of intrapulmonary pressure during machine ventilation at a given time constant of the respiratory system is the duration of expiration. At high frequencies of ventilation with short expiration times substantial gas trapping can occur with end-expiratory increase in transpulmonary pressure (inadvertent PEEP). The occlusion technique allows measurement of the intrapulmonary pressure at the airway opening because of equilibration throughout the respiratory tract. The complete intrapulmonary pressure curve can be obtained, if occlusion takes place at progressively increasing intervals after the beginning of a breath. We present a computer-assisted methode for measuring the occlusion pressure at defined time points throughout the respiratory cycle. A lung simulator is ventilated by a Sechrist ventilator. The tube leading to the simulator is occluded every 5 breaths, the time point of the occlusion being advanced progressively into each breath. Occlusion pressure is compared to intrapulmonary pressure measured directly by an intrapulmonary probe. All of this is controlled by a personal computer. We are able to demonstrate that, at ventilation frequencies of up to 600/min pressure curves measured indirectly correspond sufficiently well with pressures recorded directly in the lung model. An automatic evaluation of the measurements is possible even with a tube leakage of up to 70%.Keywords
This publication has 14 references indexed in Scilit:
- [Treatment of unilateral space-occupying pulmonary interstitial emphysema with positioning measures and high-frequency ventilation].1988
- High frequency ventilation in the neonatal periodEuropean Journal of Pediatrics, 1987
- Positive-pressure ventilation at moderately high frequency in newborn infants with respiratory distress syndrome (IRDS)Acta Anaesthesiologica Scandinavica, 1986
- Inadvertent positive end-expiratory pressure during mechanical ventilationThe Journal of Pediatrics, 1986
- Inadvertent positive end-expiratory pressure in mechanically ventilated newborn infants: Detection and effect on lung mechanics and gas exchangeThe Journal of Pediatrics, 1986
- REDUCTION OF BAROTRAUMA IN VENTILATED NEONATES BY INCREASE IN VENTILATION FREQUENCY - FIRST RESULTS OF A PROSPECTIVE COLLABORATIVE AND RANDOMIZED TRIAL OF TWO DIFFERENT VENTILATORY TECHNIQUESPediatric Research, 1985
- [High-frequency ventilation with the servo-ventilator 900 (author's transl)].1981
- Performance of neonatal ventilatorsCritical Care Medicine, 1981
- Prospective clinical comparison of two methods for mechanical ventilation of neonates: Rapid rate and short inspiratory time versus slow rate and long inspiratory timeThe Journal of Pediatrics, 1981
- Pressure Waveform and Ventilator Settings for Mechanical Ventilation in Severe Hyaline Membrane DiseaseInternational Anesthesiology Clinics, 1974