We studied the effect of positive end-expiratory pressure (PEEP) on the quantity and distribution of pulmonary extravascular water (PEW) and on lung mechanics and gas exchange in dogs with high pressure pulmonary edema. Lung volumes, intrapulmonary shunt ( ), and dynamic compliance (Cdyn) were measured before (baseline) and after (postinfusion) administration of Ringer’s Lactate (25% body weight) to maintain pulmonary wedge pressure between 35 and 40 cm H2O in 16 dogs. Animals were then randomly assigned to a control group (n=8), ventilated to maintain normocarbia for 1.5 h, and to a PEEP group (n=8) similarly ventilated with the addition of 10 cm H2O PEEP. After final measurements (1.5 h) and the injection of 51Cr tagged red blood cells, the dogs were killed and right lower lobes were excised and processed for morphometric examination and calculation of PEW by the gravimetric technique. The cuff area/vascular area ratios were measured on all extra-alveolar vessels, and total cuff H2O as well as the cuff H2O/PEW ratio was calculated. Postinfusion, increased and functional residual capacity (FRC) and Cdyn decreased in both groups. At 1.5 h the PEEP group showed significant improvement in , FRC, and Cdyn (p < 0.05). When compared with the control group, the PEEP group had similar amounts of PEW but a greater proportion of cuff H2O. We conclude that PEEP improves gas exchange and lung mechanics, and that it is associated with redistribution of lung water to the “extra-alveolar” interstitial space.This publication has 10 references indexed in Scilit:
- Regional distribution of extravascular water and hematocrit in the lungJournal of Applied Physiology, 1979
- Effect of lung inflation on perivascular cuff fluid volume in isolated dog lung lobesMicrovascular Research, 1979
- FAILURE OF POSITIVE END-EXPIRATORY PRESSURE TO DECREASE LUNG WATER-CONTENT IN ALLOXAN-INDUCED PULMONARY-EDEMAPublished by Elsevier ,1979
- EXPERIMENTAL PULMONARY-EDEMA - EFFECT OF UNILATERAL PEEP ON THE ACCUMULATION OF LUNG WATER1979
- Effect of lung volume history on rate of edema formation in isolated canine lobeJournal of Applied Physiology, 1978
- Effect of positive pressure breathing on lung lymph flow and water content in sheep.Circulation Research, 1978
- Alveolar pressure and lung volume as determinants of net transvascular fluid filtrationJournal of Applied Physiology, 1977
- Effects of continuous positive-pressure ventilation in experimental pulmonary edemaJournal of Applied Physiology, 1976
- Effect of inflation of the lung on different parts of pulmonary vascular bedJournal of Applied Physiology, 1961
- Effect of lung inflation on static pressure-volume characteristics of pulmonary vesselsJournal of Applied Physiology, 1961