Scalar calibration of vector magnetometers
- 7 January 2000
- journal article
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 11 (2) , 120-132
- https://doi.org/10.1088/0957-0233/11/2/304
Abstract
The calibration parameters of a vector magnetometer are estimated only by the use of a scalar reference magnetometer. The method presented in this paper differs from those previously reported in its linearized parametrization. This allows the determination of three offsets or signals in the absence of a magnetic field, three scale factors for normalization of the axes and three non-orthogonality angles which build up an orthogonal system intrinsically in the sensor. The advantage of this method compared with others lies in its linear least squares estimator, which finds independently and uniquely the parameters for a given data set. Therefore, a magnetometer may be characterized inexpensively in the Earth's magnetic-field environment. This procedure has been used successfully in the pre-flight calibration of the state-of-the-art magnetometers on board the magnetic mapping satellites Ørsted, Astrid-2, CHAMP and SAC-C. By using this method, full-Earth-field-range magnetometers (± 65536.0 nT) can be characterized down to an absolute precision of 0.5 nT, non-orthogonality of only 2 arcsec and a resolution of 0.2 nT.Keywords
This publication has 5 references indexed in Scilit:
- A high-precision triaxial fluxgate sensor for space applications: layout and choice of materialsSensors and Actuators A: Physical, 1997
- Transverse field effect in fluxgate sensorsSensors and Actuators A: Physical, 1997
- Development, construction and analysis of the 'OErsted' fluxgate magnetometerMeasurement Science and Technology, 1995
- Compact spherical coil for fluxgate magnetometer vector feedbackJournal of Physics E: Scientific Instruments, 1982
- Non-uniqueness of the external geomagnetic field determined by surface intensity measurementsJournal of Geophysical Research, 1970