Uniformity of ionization response of structurally diverse analytes using a chip‐based nanoelectrospray ionization source
- 3 October 2005
- journal article
- research article
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 19 (21) , 3139-3142
- https://doi.org/10.1002/rcm.2182
Abstract
The major drawback of liquid chromatography/mass spectrometry (LC/MS) for the analysis of mixtures is the non‐quantitative nature of these studies. The ionization efficiency of the various components in the mixture (e.g., a compound and its metabolites) can vary greatly and, therefore, relative intensities of signals cannot be related to relative abundance. A chip‐based nanoelectrospray ionization source was used to compare the ionization efficiencies of compounds with different physical‐chemical characteristics. The data indicate that the ionization efficiencies vary much less with the chip‐based device than by LC/MS. This was ascribed to the generation of a much higher electric field around the nozzles, which supplies a large excess of protons to the small droplets and reduces/eliminates the differences in the ionization efficiency for the analytes. Copyright © 2005 John Wiley & Sons, Ltd.Keywords
This publication has 15 references indexed in Scilit:
- IDENTIFICATION OF A NOVEL GLUTATHIONE ADDUCT OF DICLOFENAC, 4′-HYDROXY-2′-GLUTATHION-DESCHLORO-DICLOFENAC, UPON INCUBATION WITH HUMAN LIVER MICROSOMESDrug Metabolism and Disposition, 2005
- Charge competition and the linear dynamic range of detection in electrospray ionization mass spectrometryPublished by American Chemical Society (ACS) ,2004
- Quantitation of midazolam in human plasma by automated chip‐based infusion nanoelectrospray tandem mass spectrometryRapid Communications in Mass Spectrometry, 2003
- A fully automated nanoelectrospray tandem mass spectrometric method for analysis of Caco‐2 samplesRapid Communications in Mass Spectrometry, 2003
- Effect of different solution flow rates on analyte ion signals in nano-ESI MS, or: when does ESI turn into nano-ESI?Published by American Chemical Society (ACS) ,2003
- In vitro metabolite identification using fast gradient high performance liquid chromatography combined with tandem mass spectrometryRapid Communications in Mass Spectrometry, 2002
- IntroductionBritish Journal of Clinical Pharmacology, 2000
- HPLC-API/MS/MS: a powerful tool for integrating drug metabolism into the drug discovery processDrug Discovery Today, 1997
- Analytical Properties of the Nanoelectrospray Ion SourceAnalytical Chemistry, 1996
- A predictive model for substrates of cytochrome P450-debrisoquine (2D6)Chemical Research in Toxicology, 1992