This paper presents an investigation into the potential and limitations of an ETV system for the determination of total mercury, present as different species, in organic solution. The thermal and chemical stability of four mercury species in an electrothermal vaporiser, ETV, coupled to an inductively coupled plasma (ICP-MS) mass spectrometer was investigated when samples of hydrocarbon products were introduced. Calibration by the method of isotope dilution was tested with an isotopically enriched standard of mercury diethyldithiocarbamate, 201HgDDTC, in toluene. Sulfur-containing compounds, different palladium solutions and gold metals were investigated for use as matrix modifiers. A combination of Pd(NO3)2 in propanol with stabilising additives applied as a permanent modifier (A. Asheim, poster presentation, 3rd European Furnace Symposium, Prague, 1998) and thionyl chloride injected with each sample gave the most effective stabilisation of mercury species and reproducible signals with a relative standard deviation of 3% for 5 µg l−1 HgCl2. The recoveries, by isotope dilution, of HgCl2 and CH3HgCl in natural gas condensates ranged between 100 and 115%, while for Hg0 and (CH3)2Hg only 48–65% was recovered with optimised conditions. Losses of the latter two species occurred on drying of the sample in the furnace prior to heating to the pyrolysis temperature. Systematic errors in total mercury determination were, therefore, found to occur for samples containing Hg0 or (CH3)2Hg, even with isotope dilution calibration. The detection limit, based on 3s of 10 replicate measurements of the 202Hg+ signal for toluene spiked with 6 µg l−1 201HgDDTC, was 0.19 µg l−1.Keywords
This publication has 23 references indexed in Scilit:
- Stability and reactions of mercury species in organic solution†The Analyst, 1998
- Determination of Hg and Bi by electrothermal vaporization inductively coupled plasma mass spectrometry using vapor generation with in situ preconcentration in a platinum-coated graphite furnaceAnalytica Chimica Acta, 1997
- Determination of mercury in fish samples by slurry sampling electrothermal vaporization inductively coupled plasma mass spectrometrySpectrochimica Acta Part B: Atomic Spectroscopy, 1997
- Determination of Inorganic and Total Mercury in Biological Tissues by Electrothermal Vaporization Inductively Coupled Plasma Mass SpectrometryThe Analyst, 1997
- Catalytic processes in graphite furnaces for electrothermal atomic absorption spectrometrySpectrochimica Acta Part B: Atomic Spectroscopy, 1996
- Determination of metallo-organic species in lubricating oil by electrothermal vaporization inductively coupled plasma mass spectrometryAnalytica Chimica Acta, 1996
- Performance improvements in the determination of mercury species in natural gas condensate using an on-line amalgamation trap or solid-phase micro-extraction with capillary gas chromatography–microwave-induced plasma atomic emission spectrometryThe Analyst, 1996
- Removal of organic solvents by cryogenic desolvation in inductively coupled plasma mass spectrometry. Invited lectureJournal of Analytical Atomic Spectrometry, 1994
- Quantitation of Mercury in Petroleum by ETV-ICP-MSApplied Spectroscopy, 1990
- Interpreting some analytical characteristics of thermal dispersion methods used for sample introduction in atomic spectrometrySpectrochimica Acta Part B: Atomic Spectroscopy, 1988