Elemental and morphological identification of third-body particulate and calcium stearate inclusions in polyethylene components
- 1 January 2000
- journal article
- research article
- Published by Wiley in Journal of Biomedical Materials Research
- Vol. 53 (2) , 137-142
- https://doi.org/10.1002/(sici)1097-4636(2000)53:2<137::aid-jbm2>3.0.co;2-y
Abstract
Third‐body particulate such as human bone chips, hydroxyapatite, and bone cement are considered contributing factors in accelerated wear in total joint replacement. Particulate wear debris is now considered the major contributing factor in aseptic loosening of total joint replacements. The ability to distinguish between different third‐body particulate is necessary to better understand wear mechanisms when conducting implant retrieval analysis. The objective of this investigation is to demonstrate that backscattered electron imaging with correlated energy dispersive X‐ray analysis can accurately identify third‐body particulate in retrieved polyethylene components. It is important that this technique can also distinguish between third‐body particulate and normal inclusions in the polyethylene such as calcium stearate, based on the distinct morphology and elemental composition of each material. Therefore, the ability to distinguish third‐body particulate from calcium stearate inclusions is essential in gaining a better understanding of the contributing factors associated with coating separation and accelerated wear observed in clinically retrieved polyethylene components. © 2000 John Wiley & Sons, Inc. J Biomed Mater Res (Appl Biomater) 53: 137–142, 2000Keywords
This publication has 19 references indexed in Scilit:
- Polyethylene wear, osteolysis and acetabular loosening with an HA-coated hip prosthesisThe Journal of Bone and Joint Surgery. British volume, 1999
- The Impact of Sterilization Method on Wear in Knee ArthroplastyClinical Orthopaedics and Related Research, 1998
- Errors in quantitative backscattered electron analysis of bone standardized by energy‐dispersive x‐ray spectrometryScanning, 1998
- Complications With Hydroxyapatite Participate Separation in Total Hip ArthroplastyClinical Orthopaedics and Related Research, 1994
- The meaning of graylevels in backscattered electron images of boneJournal of Biomedical Materials Research, 1993
- Influence of mineral content and composition on graylevels in backscattered electron images of boneJournal of Biomedical Materials Research, 1993
- Quantitative X-Ray Analysis: Theory and PracticePublished by Springer Nature ,1992
- The Biomechanical Problems of Polyethylene as a Bearing SurfaceClinical Orthopaedics and Related Research, 1990
- Histologic, Biochemical, and Ion Analysis of Tissue and Fluids Retrieved During Total Hip ArthroplastyClinical Orthopaedics and Related Research, 1990
- Cement DiseaseClinical Orthopaedics and Related Research, 1987