Thoracic impedance as an index of body fluid balance during cardiac surgery
- 1 October 1991
- journal article
- Published by Wiley in Acta Anaesthesiologica Scandinavica
- Vol. 35 (7) , 568-571
- https://doi.org/10.1111/j.1399-6576.1991.tb03349.x
Abstract
Thoracic impedance at 2.5 (TI2.5) and 100 kHz (TI100), central venous pressure (CVP), and body fluid balance were recorded together with rectal temperature and arterial haematocrit in 15 consecutive patients subjected to coronary artery bypass grafting. I.v. fluid and blood were administered in an excess of 3.18 (1.38-9.35) 1 during the operation. TI2.5 decreased from 51.7 (39.2-66.4) to 34.9 (21.1-45.7) ohm (P = 0.001), while TI100 decreased from 41.9 (31.4-55.0) to 30.3 (18.3-40.8) ohm (P = 0.002). CVP, 6 (3-11) mmHg [0.8 (0.4-1.5) kPa], was the same before and after surgery. Temperature decreased during cardiopulmonary bypass from 35.4 (34.1-36.6) to 26.7 (22.9-31.0) degrees C and haematocrit from 39 (34-46)% to a lowest value of 27 (23-32)% (P = 0.0001). A close linear correlation between TI and body fluid balance was observed (TI2.5: r = -0.96, TI100: r = -0.95, P = 0.0001). Corrections of TI for temperature and/or haematocrit improved the correlation between TI and fluid balance to 0.99 (TI2.5) and 0.98 (TI100). The data indicate that changes in thoracic impedance can be used to monitor body fluid balance during cardiac surgery.Keywords
This publication has 16 references indexed in Scilit:
- Blood volume distribution during head‐up tilt induced central hypovolaemia in manClinical Physiology and Functional Imaging, 1991
- Atrial natriuretic peptide during head‐up tilt induced hypovolaemic shock in manActa Physiologica Scandinavica, 1990
- Cardiovascular and endocrine responses to haemorrhage in the pigActa Physiologica Scandinavica, 1990
- Transthoracic electrical impedance at 1 and 100 kHz ‐ a means for separating thoracic fluid compartments?Clinical Physiology and Functional Imaging, 1987
- Studies on the effect of controlled volume change on the thoracic electrical impedanceMedical & Biological Engineering & Computing, 1978
- Noninvasive Measurement of Intrathoracic FluidsChest, 1974
- Monitoring the Chest with ImpedanceChest, 1973
- Transthoracic electrical impedance: Quantitative evaluation of a non-invasive measure of thoracic fluid volumeAmerican Heart Journal, 1973
- Transthoracic Electrical Impedance as a Guide to Intravascular OverloadArchives of Surgery, 1971
- Clinical Evaluation of Transthoracic Electrical Impedance as a Guide to Intrathoracic Fluid VolumesAnnals of Surgery, 1970