Local Mechanical Anisotropy in Human Cranial Dura Mater Allografts
- 1 August 1998
- journal article
- Published by ASME International in Journal of Biomechanical Engineering
- Vol. 120 (4) , 541-544
- https://doi.org/10.1115/1.2798027
Abstract
Human cranial dura mater (CDM) allograft’s success as a repair biomaterial is partly due to its high mechanical strength, which facilitates its ability to form water-tight barriers and resist high in-vivo mechanical loads. Previous studies on CDM allograft mechanical behavior used large test specimens and concluded that the allograft was mechanically isotropic. However, we have quantified CDM microstructure using small angle light scattering (SALS) and found regions of well-aligned fibers displaying structural symmetry between the right and left halves (Jimenez et al., 1998). The high degree of fiber alignment in these regions suggests that they are mechanically anisotropic. However, identification of these regions using SALS requires irreversible tissue dehydration, which may affect mechanical properties. Instead, we utilized CDM structural symmetry to estimate the fiber architecture of one half of the CDM using computer graphics to flip the SALS fiber architecture map of the corresponding half about the plane of symmetry. Test specimens (20 mm × 4 mm) were selected parallel and perpendicular to the preferred fiber directions and subjected to uniaxial mechanical failure testing. CDM allografts were found to be locally anisotropic, having an ultimate tensile strength (UTS) parallel to the fibers of 12.76 ± 1.65 MPa, and perpendicular to the fibers of 5.21 ± 1.01 MPa (mean ± sem). These results indicate that uniaxial mechanical tests on large samples used in previous studies tended to mask the local anisotropic nature of the smaller constituent sections. The testing methods established in this study can be used in the evaluation of new CDM processing methods and post-implant allograft mechanical integrity.Keywords
This publication has 19 references indexed in Scilit:
- Quantification of the collagen fibre architecture of human cranial dura materJournal of Anatomy, 1998
- On the anisotropy of the canine diaphragmatic central tendonJournal of Biomechanics, 1991
- Femoral vessel coverage with dura mater after inguinofemoral lymphadenectomyGynecologic Oncology, 1991
- Treatment of periodontal furcation defects Coronally positioned flaps versus dura mater membranes in class II defectsJournal of Clinical Periodontology, 1990
- Mechanical suitability of glycerol-preserved human dura mater for construction of prosthetic cardiac valvesBiomaterials, 1984
- Storage of heart valve allografts in glycerol with subsequent antibiotic sterilisation.Thorax, 1978
- Lyophilized Human Dura as a Bladder Wall Substitute: Experimental and Clinical ResultsJournal of Urology, 1971
- Development of a Mechanical Model of the Human Head - Determination of Tissue Properties and Synthetic Substitute MaterialsSAE International Journal of Advances and Current Practices in Mobility, 1970
- The Use of Adhesive and Lyophilized Dura in the Treatment of Cerebrospinal RhinorrheaJournal of Neurosurgery, 1967
- Clinical Use of Freeze-Dried Human Dura MaterJournal of Neurosurgery, 1958