An Original Flow Diversion Device for the Treatment of Intracranial Aneurysms
- 1 March 2009
- journal article
- research article
- Published by Wolters Kluwer Health in Stroke
- Vol. 40 (3) , 952-958
- https://doi.org/10.1161/strokeaha.108.533760
Abstract
Background and Purpose— The potential for successful treatment of intracranial aneurysms by flow diversion is gradually being recognized in the clinical setting; however, the devices currently available (stents) are not designed for flow diversion. We evaluate the long-term response of an appropriately designed flow diversion device in producing thrombotic occlusion of experimental aneurysms. Methods— Three different configurations of an original flow diversion device were implanted across thirty elastase-induced aneurysm models in rabbits. Ten animals per device configuration were followed-up for 3 weeks (n=3), 3 months (n=3), or 6 months (n=4), and tissue explanted postsacrifice was sent for histology. The temporal variation in angiographic contrast intensity within each aneurysm was fitted with a mathematical model to quantify the alteration in local hemodynamics caused by the implanted device. A predictive index, called the washout coefficient, was constructed to estimate long-term aneurysm occlusion probabilities immediately after treatment with any flow diversion device. Results— The device with a porosity of 70% and pore density of 18 pores/mm 2 performed better at occluding aneurysms than devices with 70% porosity, 12 pores/mm 2 and 65% porosity, 14 pores/mm 2 . A value of the washout coefficient less than 30 predicted greater than 97% angiographic aneurysm occlusion over a period of 6 months with a sensitivity of 73% and specificity of 82%. Conclusions— The flow diversion devices effected successful and stable aneurysm occlusion. Pore density, rather than porosity, may be the critical factor modulating efficacy of such devices.Keywords
This publication has 23 references indexed in Scilit:
- Incidence of subarachnoid haemorrhage: a systematic review with emphasis on region, age, gender and time trendsJournal of Neurology, Neurosurgery & Psychiatry, 2007
- Treatment of wide-necked intracranial aneurysms with a novel self-expanding two-zonal endovascular stent deviceNeuroradiology, 2007
- A New Endoluminal, Flow-Disrupting Device for Treatment of Saccular AneurysmsStroke, 2007
- In Vitro Evaluation of Flow Divertors in an Elastase-Induced Saccular Aneurysm Model in RabbitJournal of Biomechanical Engineering, 2007
- Endovascular treatment of intracranial aneurysms with parent vessel reconstruction using balloon and self expandable stentsActa Neurochirurgica, 2006
- International subarachnoid aneurysm trial (ISAT) of neurosurgical clipping versus endovascular coiling in 2143 patients with ruptured intracranial aneurysms: a randomised comparison of effects on survival, dependency, seizures, rebleeding, subgroups, and aneurysm occlusionThe Lancet, 2005
- Morphology of elastase-induced cerebral aneurysm model in rabbit and rapid prototyping of elastomeric transparent replicasBiorheology, 2005
- Initial Clinical Experience with a New Self-Expanding Nitinol Stent for the Treatment of Intracranial Cerebral Aneurysms: The Cordis Enterprise Stent2005
- Usefulness of the Neuroform Stent for the Treatment of Cerebral Aneurysms: Results at Initial (3–6-mo) Follow-upNeurosurgery, 2005
- Efficacy and current limitations of intravascular stents for intracranial internal carotid, vertebral, and basilar artery aneurysmsJournal of Neurosurgery, 1999