Performance of the New Bayer VERSANT HCV RNA 3.0 Assay for Quantitation of Hepatitis C Virus RNA in Plasma and Serum: Conversion to International Units and Comparison with the Roche COBAS Amplicor HCV Monitor, Version 2.0, Assay
Open Access
- 1 March 2002
- journal article
- research article
- Published by American Society for Microbiology in Journal of Clinical Microbiology
- Vol. 40 (3) , 788-793
- https://doi.org/10.1128/jcm.40.3.788-793.2002
Abstract
We have evaluated the VERSANT HCV RNA 3.0. Assay (HCV 3.0 bDNA assay) (Bayer Diagnostics, Berkeley, Calif.), which is an improved signal amplification procedure for the HCV 2.0 bDNA assay for the quantitation of hepatitis C virus (HCV) RNA in serum or plasma of HCV-infected individuals. The HCV 3.0 bDNA assay has a linear dynamic range of 2.5 × 103 to 4.0 × 107 HCV RNA copies per ml (c/ml). The performance of the HCV 3.0 bDNA assay was evaluated using three different test panels. An overall specificity of 96.8% relative to the detection limit of the HCV 3.0 bDNA assay was found. The intra- and interrun reproducibilities for both the dilution panel and the NAP (AcroMetrix, Benicia, Calif.) panel were consistent with coefficients of variation of less than 9%. Quantitation with the HCV 3.0 bDNA assay was linear over the entire range of both panels (ranges of 4.4 × 103 to 3.5 × 106 c/ml and 5 × 103 to 2 × 106 IU/ml, respectively), with correlation coefficients of 0.999, slopes close to one, and intercepts close to zero. The regression equation indicated that 1 IU corresponded to about 4.8 copies of HCV RNA. A correlation coefficient of 0.941 was found for HCV RNA values (in international units per milliliter) obtained from the HCV 3.0 bDNA assay and the HCV Monitor version 2.0 assay (HCV Monitor 2.0 assay) (Roche Diagnostic Systems, Branchburg, N.J.). Quantitative results obtained close to the lower limit of the HCV 3.0 bDNA assay might imply that its lower limit should be reconsidered and raised, if necessary. It appeared that quantitation values obtained from the HCV Monitor 2.0 assay of between 5 × 102 and 105 IU/ml were in general higher than those obtained from the HCV 3.0 bDNA assay, whereas values obtained from the HCV Monitor 2.0 assay were underestimated for samples with HCV RNA levels above 105 IU/ml.Keywords
This publication has 19 references indexed in Scilit:
- Standardized hepatitis C virus RNA panels for nucleic acid testing assaysJournal of Clinical Virology, 2001
- Peginterferon Alfa-2a in Patients with Chronic Hepatitis CNew England Journal of Medicine, 2000
- Standardization of Hepatitis C Virus RNA QuantificationHepatology, 2000
- Establishment of the First International Standard for Nucleic Acid Amplification Technology (NAT) Assays for HCV RNAVox Sanguinis, 1999
- EASL International Consensus Conference on Hepatitis CParis, 26–27 February 1999Consensus StatementJournal of Hepatology, 1999
- Interferon Alfa-2b Alone or in Combination with Ribavirin as Initial Treatment for Chronic Hepatitis CNew England Journal of Medicine, 1998
- Randomised trial of interferon α2b plus ribavirin for 48 weeks or for 24 weeks versus interferon α2b plus placebo for 48 weeks for treatment of chronic infection with hepatitis C virusPublished by Elsevier ,1998
- Hepatitis C Viral Dynamics in Vivo and the Antiviral Efficacy of Interferon-α TherapyScience, 1998
- Quantification of the initial decline of serum hepatitis c virus RNA and response to interferon alfaHepatology, 1998
- Use of an indirect pharmacodynamic stimulation model of MX protein induction to compare in vivo activity of interferon alfa-2a and a polyethylene glycol-modified derivative in healthy subjectsClinical Pharmacology & Therapeutics, 1996