Imaging Articular Cartilage Defects with 3D Fat-Suppressed Echo Planar Imaging: Comparison with Conventional 3D Fat-Suppressed Gradient Echo Sequence and Correlation with Histology
- 1 January 1998
- journal article
- clinical trial
- Published by Wolters Kluwer Health in Journal of Computer Assisted Tomography
- Vol. 22 (1) , 8-14
- https://doi.org/10.1097/00004728-199801000-00002
Abstract
Our goal was to shorten examination time in articular cartilage imaging by use of a recently developed 3D multishot echo planar imaging (EPI) sequence with fat suppression (FS). We performed comparisons with 3D FS GE sequence using histology as the standard of reference. Twenty patients with severe gonarthrosis who were scheduled for total knee replacement underwent MRI prior to surgery. Hyaline cartilage was imaged with a 3D FS EPI and a 3D FS GE sequence. Signal intensities of articular structures were measured, and contrast-to-noise (C/N) ratios were calculated. Each knee was subdivided into 10 cartilage surfaces. From a total of 188 (3D EPI sequence) and 198 (3D GE sequence) cartilage surfaces, 73 and 79 histologic specimens could be obtained and analyzed. MR grading of cartilage lesions on both sequences was based on a five grade classification scheme and compared with histologic grading. The 3D FS EPI sequence provided a high C/N ratio between cartilage and subchondral bone similar to that of the 3D FS GE sequence. The C/N ratio between cartilage and effusion was significantly lower on the 3D EPI sequence due to higher signal intensity of fluid. MR grading of cartilage abnormalities using 3D FS EPI and 3D GE sequence correlated well with histologic grading. 3D FS EPI sequence agreed within one grade in 69 of 73 (94.5%) histologically proven cartilage lesions and 3D FS GE sequence agreed within one grade in 76 of 79 (96.2%) lesions. The gradings were identical in 38 of 73 (52.1%) and in 46 of 79 (58.3%) cases, respectively. The difference between the sensitivities was statistically not significant. The 3D FS EPI sequence is comparable with the 3D FS GE sequence in the noninvasive evaluation of advanced cartilage abnormalities but reduces scan time by a factor of 4.Keywords
This publication has 22 references indexed in Scilit:
- Accuracy of fat-suppressed three-dimensional spoiled gradient-echo FLASH MR imaging in the detection of patellofemoral articular cartilage abnormalities.Radiology, 1996
- Detection of knee hyaline cartilage defects using fat-suppressed three-dimensional spoiled gradient-echo MR imaging: comparison with standard MR imaging and correlation with arthroscopy.American Journal of Roentgenology, 1995
- Fat-suppressed spoiled GRASS imaging of knee hyaline cartilage: technique optimization and comparison with conventional MR imaging.American Journal of Roentgenology, 1994
- Quantification of articular cartilage in the knee with pulsed saturation transfer subtraction and fat-suppressed MR imaging: optimization and validation.Radiology, 1994
- Echo-planar imaging of the liver with a standard MR imaging system.Radiology, 1993
- Width of the articular cartilage of the hip: quantification by using fat-suppression spin-echo MR imaging in cadavers.American Journal of Roentgenology, 1992
- Knee Joint Hyaline Cartilage DefectsJournal of Computer Assisted Tomography, 1992
- MR imaging of joints: analytic optimization of GRE techniques at 1.5 T.American Journal of Roentgenology, 1992
- Magnetic resonance imaging of traumatic knee articular cartilage injuriesThe American Journal of Sports Medicine, 1991
- Chondromalacia patellae: assessment with MR imaging.Radiology, 1987