Marked Discordance Between Dynamic and Passive Diastolic Pressure-Volume Relations in Idiopathic Hypertrophic Cardiomyopathy
- 1 July 1996
- journal article
- Published by Wolters Kluwer Health in Circulation
- Vol. 94 (1) , 52-60
- https://doi.org/10.1161/01.cir.94.1.52
Abstract
Background Dynamic diastolic pressure-volume curves measured during filling (PVR fill ) in patients with idiopathic hypertrophic cardiomyopathy (HCM) are often considerably shallower than would be anticipated if one assumed high chamber stiffness. We hypothesized that these curves deviate markedly from the passive end-diastolic pressure-volume relation (EDPVR) and explored the mechanisms for such a discordance. Methods and Results We used invasive pressure-volume analysis and conductance catheter methodology to study 42 patients. Nine had HCM, and the remaining patients comprised three comparison groups: 11 with normal left ventricular (LV) function, 13 with LV hypertrophy secondary to chronic hypertension (LVH-HTN), and 9 with idiopathic dilated cardiomyopathy (DCM). EDPVRs were recorded during balloon catheter obstruction of inferior vena cava inflow. In normal subjects, LVH-HTN patients, and DCM patients, PVR fill curves deviated only slightly from the passive EDPVR. In striking contrast, HCM patients displayed a flat PVR fill that was very different from the steep EDPVR. On reduction of preload, PVR fill relations in HCM shifted downward in parallel, with a net pressure decline at the same chamber volume of −10±4 mm Hg. This staircaselike shift was much less in the other patient groups (−2±2 mm Hg; P <.001). The unusual behavior in HCM could not be attributed directly to increased viscosity, enhanced pericardial constraint, or preload dependence of isovolumic relaxation. Regional heterogeneity of relaxation may play a role; however, we speculate that the major mechanism relates to the unique fiber and chamber architecture seen with HCM and possibly to enhanced ventricular interaction. Conclusions Elevated LV filling pressures in HCM are not due simply to a stiff cavity but also reflect a major influence of offset pressures that vary with chamber loading. The large disparity between flat pressure-volume relations during filling and steep end-diastolic relations appears unique to HCM. This indicates that caution should be used in the interpretation of stiffness results derived from steady-state data and suggests that therapies that alter cavity geometry and/or reduce interaction may markedly influence LV diastolic pressures in HCM.Keywords
This publication has 33 references indexed in Scilit:
- Validation of a method for noninvasive measurement of central arterial pressure.Hypertension, 1993
- Left ventricular systolic and diastolic function in the hypertrophied ventricle.Japanese Circulation Journal, 1990
- Hypertrophic CardiomyopathyNew England Journal of Medicine, 1987
- A mechanism for the nitroglycerin-induced downward shift of the left ventricular diastolic pressure-diameter relationThe American Journal of Cardiology, 1986
- Effects of verapamil on left ventricular systolic and diastolic function in patients with hypertrophic cardiomyopathy: pressure-volume analysis with a nonimaging scintillation probe.Circulation, 1983
- Mechanical interaction between the ventriclesBasic Research in Cardiology, 1983
- Diastolic function and myocardial structure in patients with myocardial hypertrophy. Special reference to normalized viscoelastic data.Circulation, 1981
- Left ventricular relaxation and filling pattern in different forms of left ventricular hypertrophy: An echocardiographic studyThe American Journal of Cardiology, 1980
- Catenoid shape of the interventricular septum: possible cause of idiopathic hypertrophic subaortic stenosis.Circulation, 1978
- Left ventricular compliance: Mechanisms and clinical implicationsThe American Journal of Cardiology, 1976